Solid sealed pole vacuum circuit breaker 12KV for indoor electric panel

Voltage: 12-24KV

Current: Max 2000A

Breaking current: 20KA

Type: withdrawable/Fixed


Product overview

Vacuum circuit breaker: It is a new type of high-voltage circuit breaker developed in the 1960s (for example, the picture at the beginning of this article is ZN28-12 indoor high-voltage vacuum circuit breaker), which uses vacuum to extinguish arcs. Its advantages are small size, light weight, fast action, fireproof and explosion-proof, low noise and so on. At present, there is a trend to replace other circuit breakers, mainly used in substations below 35KV and places requiring frequent operations in industrial and mining enterprises.


Technical Parameters

No.ItemUnitParameter
1Rated voltageKV12
2Rated frequencyHz50/60
3

Rated insulation level

1min power frequency withstand voltage(r. m. s)

KV

42(phase-to-phase, phase-to-earth)

48(across the isolating distance)

Lighting impulse withstand voltage (peak)

75(phase-to-phase, phase-to-earth)

85(across the isolating distance)


4


Rated current


A

63063012501600
1250125016002000
20002500
25003150
4000
5Rated short-circuit breaking current

KA

202531.540
6Rated short-time withstand current202531.540
7Rated short-circuit marking current506380100
8Rated peak withstand current506380100
9Rated duration of short-circuits4
10Rated operating sequenceO-0.3s-O/C-180s-O/C
11Breaking times of rated short-circuit currentTimes30/20 times(40KA)
12Mechanical enduranceOps20000
13Rated single capacitor bank breaking current

A

630
14Rated back-to-back capacitor bank breaking current400
15Double-earth fault breaking current27.4
16Allowable maximum contact erosion

mm

3
17Clearance between open contacts10±1
18Over stroke3.5±0.5
19Non-simultaneity of 3-phase opening and closing

ms


≤2
20Bounce duration of contact closing≤2
21Average breaking speed (instant breaking 6mm)

m/s


1.1±0.2
22Average making speed0.8±0.2
23Making time

ms


≤100
24Breaking time≤50

25


Resistance of each phase main circuit


μ Ω

630A≤50
1250A≤45
1600A~2000A≤35
≥2500A≤25
26Contact breaking bounce amplitudemm≤2

27

Rated operating voltageRated operating voltage(V)AC/DC

V

24*110220
Scope of normal operation voltageOpening:65%-120% rated voltage, in case the voltage is lower than 30% rated voltage, opening operation is not allowed
28Rated voltage of energy storage motorVAC110/220,DC110/220
29Energy storage timeS≤15