MV Metalclad Circuit Breaker Switchgear For Single Busbar Segmented System

Brand Name:Knkong
Certification:IEC
Model Number:KYN28A-12KV
Minimum Order Quantity:1
Delivery Time:30 days
Payment Terms:L/C, T/T
Contact Now

Add to Cart

Active Member
Location: Zhengzhou Henan China
Address: No. 25 Street , Hanghai Road, Zhengzhou,Henan,China
Supplier`s last login times: within 11 hours
Product Details Company Profile
Product Details

Vacuum circuit breaker type switchgear KYN28 for medium voltage using


Voltage: 3.6KV 6.6KV 12KV 24KV

Current: 630A 1250A 2000A

Type: withdrawable

Circuit breaker: vacuum


General

The rated voltage of KYN28-12KV switchgear covers 3.6~24kV, three-phase, AC, 50/60Hz, complete set of power distribution equipment for a single busbar segmented system.
It is mainly used for the transmission of small generators in power plants, the power distribution of industrial enterprises, the transmission of power system substations, and the start of large high-voltage motors. The function of the KYN28 switch cabinet is to control, protect and monitor the system.
The KYN28 switchgear we made is in line with IEC and GB3906-91 standards.
It can use domestic VS1, ABB's VD4, Siemens domestic-made ZN65A 3AH5, GE's VB2, and other vacuum circuit breakers.

Service environment
1. Air temperature: -25℃~+40℃
2. Humidity: Monthly average humidity 95%; Daily average humidity 90%.
3. Altitude :≤ 2500m
4. Ambient air not apparently polluted by corrosive and flammable gas, vapor, etc.
5. No frequent violent shake


Fully type-tested

The device passes all tests required by international (IEC) standards. When each switchgear goes through regular factory tests before leaving the factory.
These tests are functional inspections of the equipment based on the characteristics of each device.

Technical data

No.ItemUnitParameter
1Rated voltagekV3.6~24
2Rated frequencyHz50/60
3Rated currentA630,1250,1600,2000,2500,3150,4000
4Branch busbar Rated current630,1250,1600,2000,2500,3150,4000
5The main busbar Rated current630,1250,1600,2000,2500,3150,4000
6

1min Power frequency

withstand voltage

wetKV3850/60
dry4860/65
7Lightning impulse withstand voltagekV7595/125
8Rated short circuit breaking current (peak)KA40/50/63/80/100
9Short-time withstand current(4s)20/25/31.5/40
10Protection typeIP4X for housing

China MV Metalclad Circuit Breaker Switchgear For Single Busbar Segmented System supplier

MV Metalclad Circuit Breaker Switchgear For Single Busbar Segmented System

Inquiry Cart 0