CB MV Metal Clad Switchgear KYN61A 36KV Switchgear

Brand Name:KNKONG
Certification:CB,ISO
Model Number:KYN61A-40.5KV
Minimum Order Quantity:1
Delivery Time:15 working days
Payment Terms:L/C, T/T
Contact Now

Add to Cart

Active Member
Location: Zhengzhou Henan China
Address: No. 25 Street , Hanghai Road, Zhengzhou,Henan,China
Supplier`s last login times: within 11 hours
Product Details Company Profile
Product Details
33KV switchgear panel, metal-clad MV switchgear power switchgear panel

33KV switchgear panel, metal-clad MV switchgear power switchgear panel

KYN61 metal-clad medium voltage switchgear,
Knkong,ABB or Schneider inside
40.5KV, three-phase, AC 50/60Hz
Can be equipped with VS1-40.5 VCB
Meets IEC standard
Design switchgear plan as SLD (Single Line Drawing)
Inquire

Product Introduction

KYN61-40.5 Metal-enclosed switchgear 3P AC 50Hz, rated voltage of 40.5kV suitable for power plant, substation and power distribution to industrial and mining enterprises, railway transportation as the acceptance and distribution of electric energy. And the implementation of control, protection and monitoring function of circuit. The utility model has the advantages of flexible operation, reliable electrical performance, long service life, convenient maintenance.

KNY61-60.5 can be equipped with ABB/Schneider/Knkong series 40.5KV VCB.


Service environment:

a) Air temperature: -25℃~+40℃

b) Humidity:Monthly average humidity 95%; Daily average humidity 90% .

c) Altitude2500m

d) Ambient air not apparently polluted by corrosive and flammable gas, vapor etc.

e) No frequent violent shake


Technical data

ItemsUnitData
Rated VoltageKV40.5
Rated FrequencyHz50
Rated CurrentA1250,1600,2000
Rated Short-circuit Breaking CurrentKA25,31.5
Rated Making Current (Peak)KA63,80
4s Thermal Stability CurrentKA25,31.5
Rated Dynamic Current (Peak)KA63,80
Rated Insulation Level1min Power Frequency Withstand Voltage (r.m.s)KV95
Lightning Impulse Withstand Voltage (Peak)KV185
1min Power Frequency Voltage Across the open gap (r.m.s)KV118
Lightning Impulse Withstand Voltage Across the open gap (Peak)KV215
Enclosure Protection Class

Enclosure IP4X,

Between Compartments IP2X

Enclosure Dimension (Width*Depth*Height)mm1400*2800*2600
1600*2800*2600
Type of Circuit BreakerVCB:ZN85-40.5
SF6 Circuit Breaker

*Note: order switchgear should provide SLD(Single-line diagram) by customer


Main components characteristics:

VS1-40.5 Indoor Vacuum Circuit Breaker

Rated voltage: 40.5kV

Rated current: 630 1250 1600 2000 2500A

Rated short circuit breaking current: 20 25 31.5KA

Mechanical life: 20,000 times


VS1-40.5 Technical data

ItemsUnitDate
Rated voltage

KV

40.5
Rated short-time power frequency withstand voltage (1min)95
Rated lightning impulse withstand voltage (peak)185
Rated freqHz50/60
Rated currentA1250 1600 2000 2500 4000
Rated short-circuit drop-out currentKA25 31.5
Rated short time withstand current25 31.5
Rated short time continual times4
Rated peak withstand currentKA63 80
Rated short-circuit closing current63 80
Rated single/ back-to-back capacitor bank drop-out currentA630/400
Opening time (rated volt.)ms35~60
Closing time (rated volt.)50~100
Mechanical lifetimes20000
Rated break times for rated short drop out currents20
Rated operation voltageVAC110/220 DC110/220
Rated current of power storing motorW230
Average opening speedm/s1.6~2.0
Average closing speed0.5~0.8
Rated operation procedure

opening-0.3s-closing

opening-180s-closing opening


Knkong Electric 33KV switchgear has served the international market over 10 years.

Appreciate for the hard work of our professional electrical engineering team, the international evaluation of our 33kv switchgear is positive.

China CB MV Metal Clad Switchgear KYN61A 36KV Switchgear supplier

CB MV Metal Clad Switchgear KYN61A 36KV Switchgear

Inquiry Cart 0