Add to Cart
50WW600 Cold Rolled Silicon Steel Coil non-oriented silicon steel sheets 0.5mm
Magnetic induction intensity is the number of magnetic field lines
passing through the core per unit cross-sectional area, also known
as magnetic flux density, which represents the magnetization
ability of the material, and the unit is T.The magnetic induction intensity of silicon steel plate is high,
the magnetic current of the iron core (also known as no-load
current) is reduced, and the copper loss and iron loss are
decreased, which can save energy.When the power of the motor and transformer is unchanged, the
magnetic induction intensity is high, the design Bm can be
improved, and the cross-sectional area of the iron core can be
reduced, which reduces the volume and weight of the iron core, and
saves the consumption of silicon steel plates, wires, insulation
materials and structural materials, thus reducing the total loss
and manufacturing cost of the motor and transformer.And is conducive to the manufacture, installation and
transportation of large transformers and large motors.
Dimensions of Products
Available thickness (mm) | Availiable width range (mm) | Inside Diameter (mm) | |||||
0.15,0.20 | 950-1000 | 508±10 | |||||
0.30,0.35,0.50,0.70,0.75,0.80,0.85 | 1000~1250 | 508±10 |
Typical Mechanical Properties
Grade | Yield strength Rp | Tensile strength Rm | Elongation | Hardness HV5 | Lamination factor % | |||
(N/mm2) | (N/mm2) | (%) | ||||||
L | C | L | C | L | C | |||
50WW600 | 280 | 295 | 410 | 425 | 40 | 42 | 130 | 98.5 |
Standard Magnetic Properties
Grade | Norminal thickness | Theoretical density | Max. Core loss | Min Induction | Min. Number of bends | Min. Lamination factor | |
P1550 | 50Hz | 400Hz | |||||
mm | kg/dm3 | W/kg | B5000 | B2000 | % | ||
50WW600 | 0.5 | 7.75 | 4.20 | 1.67 | / | 12 | 97.5 |