0.21 MPa Desktop Autoclave Sterilizer High Pressure Relief Valve

Brand Name:HAIYING
Certification:CE certificate
Model Number:BTD23-A
Minimum Order Quantity:1 Set
Delivery Time:5-8 work days
Payment Terms:L/C, D/A, D/P, T/T, Western Union, MoneyGram
Contact Now

Add to Cart

Active Member
Address: Room 309, Huineng Building, 38 Huaneng Road
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details

High Pressure Relief Valve Electric Heating Automatic Desktop Autoclave Sterilizer

Desktop Autoclave Sterilizer Advantage:

◆ Build-in open type water tank

The sterilizer adopts easy-clean open type water tank which can support repeated program running if fully injected

with water.

◆ High-efficiency ultimate vacuum

The sterilizer adopts high-efficiency low noise vacuum system which has excellent effects.

◆ New user interface

LCD screen can display the temperature, pressure, time, running state and fault alarm information, such as sterilization information more intuitive

◆ Safety equipment is complete

Overtemperature multiple control and automatic protection device, the steam generator protection, safety door interlock, double overpressure protection, electronic circuit safety device.

◆ Automatic door structure

Step with quick and convenient operation, and adopt more, moving and pressing technology, make the door seal is more reliable, one-click doors, faster.

◆ Full automatic operation

A bare program, packaging, rubber, custom program, fast, such as sterilization procedures and B&D test, vacuum test program and preheating and drying auxiliary class.

◆ Powerful vacuum drying system

Equipment residual humidity no more than 0.2% after drying, dressings residual moisture after drying, degree of not more than 1%, guaranteed to break the vacuum air aseptic air, sterile items to avoid pollution again.

ModelBTD23-A
Nominal voltageAC100/220v , 50HZ /60HZ
Rated working pressure0.11 M Pa/0.21 M Pa
Chamber volume23L
Net weight60KG

Desktop Autoclave Sterilizer Operating specifications

Preparation before use:

◆ Water tank, add pure water or as required in accordance with the requirements after connecting water, connection equipment power supply.

◆ Sterilizer, turn on the power supply, the power switch in the on state, to be prepared for the program is running;

◆ According to the specified requirements or load type, select the BD program or preheat (for example, if is the class B load with a cavity, generally need to first run BD application, if all are exposed solid equipment can run the preheating process) onto a BD indicate the operator's name or code, date, such as tag, run out into the south in BD experimental procedures, monitoring equipment without leakage, the equipment is normal:

◆ stay sterilization package, strapping not too tight, the built-in chemical indicator CARDS, chemical indicator tape is stuck outside.

Operation after use

◆ open cupboard door, will the power switch in the off state, to cut off the equipment power supply:

◆ Water quality is poor or run after five fire bacteria process must change water:

◆ Evaporator, monthly cleaning (cleaning method in accordance with the manual)

◆ At the end of the daily work, sterilizer should be kept clean inside and outside, you should use a clean cloth and water chamber dirt" clean, according to the instruction weekly maintenance, monthly maintenance.