Spring Type Safety Valve High Pressure Relief Valve Vertical
Autoclave Sterilizer
Vertical Autoclave Sterilizer Advantage:
◆ Fully stainless high-alloy steel structure
◆ Digital window LCD display working status
◆ Auto discharge the cool air, and steam discharging automatically
after sterilization
◆ Automatic off of heating elements at reducing of a water level
◆ Automatically shut off with beep reminding after sterilization
Chamber volume | 40Lφ340*425MM |
working pressure | 0.1-0.22MPa |
Working temperature | 120-134℃ |
Max working pressure | 0.23 Mpa |
Heat average | ≤±1℃ |
Timer | 0~99min or 0~99hour59min |
Adjustment of temperature | 105~134℃ |
Power | 3.5KW |
Overall dimension | 570*570*1250MM |
G.W/N.W | 55KG |
Vertical autoclave sterilizer standard operating procedures cool
after use:
the sterilization after termination of power off first, small cock
the vent valve handle exhaust (attention should be paid to prevent
steamOutburst cause burns!) , after 5 minutes, back pressure gauge
pointer "0" position after opening the container cover. When you
start the container lid must put down the wing nut evenly unscrew
them one by one, can remove the container cover.
Note: the liquid or glass containers costumed disinfection, do not
immediately after expiration of the sterilization exhaust, exhaust
conducts rapidly On, fluid boiling and overflow may even make
containers burst. Should make its natural cooling 20-30 minutes, or
when the pressure gauge pointer back to zero, must open the
deflated idle, can open the container cover to take out the
sterilized items.
Vertical autoclave sterilizer safety and maintenance:
1 this sterilizer is steam pressure container, in the use of impact
of avoid by all means, overpressure is forbidden to use; Such as
pressure gauge pointer indicated pressure has been more than 0. 165
Mpa and the relief valve, throw not exhaust, should immediately
stop the use and safetyValve may have failed, should repair,
replace the relief valve, and ensure the safety valve performance
qualified can be put into use again.The relief valve should check
at least once or twice a year, to keep its proper sensitivity and
accuracy, so as not to cause safety accidents.
2 pressure gauge pointer before use should be in "0" position,
otherwise, the response to the pressure gauge for repair or
replacement.Pressure gauge, should check at least once or twice a
year, to keep its proper sensitivity and accuracy, so as not to
cause the safety accident.
3 termination after use of the water in the container should be put
the net, the container wall and on the surface of the electric
heating tube in time scale slipping, so that more beneficial to
sterilization quality, and save energy and prolong service life.
4 sealing washer is wearing parts, often should check the sealing
washer, when can not meet the sealing performance or already
deformation or already aging hardening should be replaced in a
timely manner.
5 sterilization items needed for the sterilization time, steam
pressure/temperature corresponding relationship see table (for
reference only) disinfection sterilization time needed for items,
steam pressure/temperature corresponding to the table (for
reference only)