SMC PFM750-01L-F Digital Flow Switch

for Air New Original


Brief Introduction of SMC PFM750-01L-F Digital Flow Switch for Air New Original


The SMC PFM750-01L-F is a digital flow switch typically used for monitoring and managing air flow in various industrial applications.


Specification of SMC PFM750-01L-F Digital Flow Switch for Air New Original


Product Name

SMC PFM750-01L-F Digital Flow Switch for Air New Original


BrandSMC
Part NoPFM750-01L-F
Rated flow range Dry air, N2, Ar1 to 50 l/min

Rated flow range

CO2

1 to 25 l/min

Displayed flow

Dry air, N2, Ar


1 to 52.5 l/min

Displayed flow

CO2


1 to 26.2 l/min

Set flow

Dry air, N2, Ar


0 to 52.5 l/min

Set flow

CO2


0 to 26.2 l/min
Minimum unit setting0.1 l/min
Accumulated pulse flow rate exchange value0.1 l/pulse
Indication unit

Real-time flow rate l/min,


CFM x 10-2 Accumulated flow l, ft3 x 10-1


Linearity

Display accuracy: ±3%F.S. or less (Fluid: Dry air) Analogue output accuracy: ±5%F.S. or less


Operating pressure range–100 kPa to 750 kPa
Rated pressure range–70 kPa to 750 kPa

Warning


1. Use the switch within the specified voltage range. Using the switch outside this range may cause malfunctions and damage, as well as electric shock or fire.


2. Do not exceed the maximum allowable load. Loads exceeding the maximum allowable load may damage the switch.


3. Do not use loads that generate surges. Even if the switch's output circuit has surge protection devices installed, repeated application of surges


may damage it. When directly operating devices that generate surges, such as relays and solenoid valves, use loads with built-in surge


absorbers.


4. Be sure to check the applicable fluid. This switch is not explosion-proof. To prevent fire, do not use it with flammable gases or fluids.


5. Monitor the voltage drop within the switch. If the load operates below the specified voltage, it may fail even if the pressure switch is operating


normally. Therefore, after determining the load voltage, the following formula should be followed.