Brief Description

PHiliphh IntelliVue G5 M1019A Gas Anesthesia Module - is a compact medical product that works with IntelliVue patient monitors via RS232 serial interface. They measure airway gases in ventilated patients receiving general gas anesthesia or emerging from anesthesia and present them on the patient monitor screen for medical staff to view patient status.

These modules generate graphical waveform data and inspired and end-expiratory digital data for the following gases:

• CO2

• N2O

• Two volatile anesthetics (IntelliVue G5)

• O2

• It also generates data for MAC (minimum alveolar concentration) and the patient's airway respiratory rate (awRR).


► Specification

Physical Specifications
Size (H x W x D):93 x 306 x 232 mm (3.66 x 12.05 x 9.13 in)
Weight:less than 4 kg (7.94 lb)
Environmental Specifications
Operating Temperature:10 - 40°C (50 - 104°F)
Storage Temperature:-20 - 65°C (-4 - 149°F)
Humidity Limit (Operating):5 - 90% RH max @ 40°C (104°F). non-condensing
Humidity Limit (Storage):5 - 95% RH max @ 65°C (149°F). non-condensing
Altitude Range (Operating):-305 - 2900m (-1,000 - 9,515ft)
Altitude Range (Storage):-305 - 5000m (-1,000 - 16,404ft)
Warm-up Time:1-2 minutes to measure CO2, less than 6 minutes for full accuracy specifications

CO2 Measurement
Range:0 - 76 mmHg
Accuracy:0.5 vol% or 12% relative, whichever is greater
Resolution:1 mmHg
Rise-time:350 msec typical
AWRR derived from CO2 Waveform
Range:0 - 60 rpm
Accuracy:± 1 rpm
Resolution:1 rpm
Detection Criteria:adaptive threshold
N2O Measurement
Range:0 - 100vol%
Accuracy:2.0 vol% + 8% relative
Resolution:1 vol%
Rise-time:500 msec typical
O2 Measurement
Range:5 - 100vol%
Accuracy:± 3 vol%
Resolution:1 vol%
Rise-time:500 msec typical

► Detailed Photos


► Water Trap

PHiliphh IntelliVue G5 M1019A Gas Anesthesia Module is used with a watertrap. The watertrap consists of two water separation filters, two water fuses, and a water reservoir. The gas sample from the patient may contain liquid that is separated from the gas at the first water separation filter. The gas will then be divided into two paths. One is the "measurement" path, in which the main part of the total gas flow (including water vapor) continues to flow on the "dry" side of the separation filter. The other is the "drainage" path, and a smaller part of the total flow continues to flow on the "wet" side of the filter through the water reservoir. At the pump, the two gas paths are recombined.


Thanks for your interest in PHiliphh IntelliVue G5 M1019A Gas Anesthesia Module Including Water Trap Used-Good for Hospital, please feel free to contact me. Thank you for your time and wish you have a happy life.

China PHiliph IntelliVue G5 M1019A Gas Anesthesia Module Including Water Trap for Hospital supplier

PHiliph IntelliVue G5 M1019A Gas Anesthesia Module Including Water Trap for Hospital

Inquiry Cart 0