10097559 PSR-11-75-KE13PB oxygen sensor for Covidien PB760 PB840 PB980 Puritan Bennett Ventilator Machine


Oxygen sensor calibration test


Test the oxygen sensor calibration as follows:


1. Connect the ventilator oxygen tubing to a known source of 100% O2 (e.g., a medical oxygen cylinder). Press the 100% O2/CAL button for 2


minutes or the INCREASE O2 button for 2 minutes to calibrate the oxygen sensor. Once the button light turns off, proceed to the next step.


2. Connect the ventilator oxygen tubing to another known source of 100% O2 (e.g., a second medical oxygen cylinder).


3. Set %O2 to the following values ​​and wait one minute for each monitored value to stabilize: 21% 40% 90%


4. Observe the upper display to ensure that the O2 value (% O2 delivered) is within 3% of each setting within one minute of selecting each


setting.


Oxygen Sensor Calibration Button: Older ventilators use the 100% O2/CAL 2 minutes button, while newer ventilators use the INCREASE O2 2


minutes button. Provides 100% oxygen (if available) for two minutes and calibrates the oxygen sensor. The green light on this button will


illuminate and a message (100% O2 Cal in Progress) will appear on the lower touchscreen to indicate 100% O2 delivery is active. If you press the


O2 button again, the system will restart the two-minute delivery interval. Press CANCEL to stop calibration. For information on calibrating the


oxygen sensor, see page TR 15-5.


Alarm Messages


If you see this O2 Sensor message, it means that background checks have identified a problem with the oxygen sensor (sensor error or not calibrated). Patient ventilation will not be affected. And you can:


• Press 100% O2 CAL or O2 INCREASE for 2 minutes to recalibrate the oxygen sensor.


• Disable the oxygen sensor.


• Replace the oxygen sensor.


Specification of 10097559 PSR-11-75-KE13PB oxygen sensor for Covidien PB760 PB840 PB980 Puritan Bennett Ventilator Machine


Product Name

PSR-11-75-KE13PB 10097559 oxygen sensor for Covidien PB760 PB840 PB980 Puritan Bennett Ventilator Machine


BrandCovidien
Part No

PSR-11-75-KE13PB 10097559


Application

PB760 PB840 PB980 Puritan Bennett Ventilator Machine


MOQOne piece
ConditionOriginal /Compatible new
Warranty90 days

Photo


Below photo is PSR-11-75-KE13PB 10097559 oxygen sensor ,which can be used for Covidien PB760 PB840 PB980 Puritan Bennett Ventilator Machine .For more details ,please feel free to contact us .



Thank you so much for your attention .If you're interested in 10097559 PSR-11-75-KE13PB Oxygen Sensor For Covidien PB760 PB840 PB980 Puritan Bennett Ventilator Machine ,feel free to contact us .Thank you .

China 10097559 PSR-11-75-KE13PB Oxygen Sensor For Covidien PB760 PB840 PB980 Puritan Bennett Ventilator Machine supplier

10097559 PSR-11-75-KE13PB Oxygen Sensor For Covidien PB760 PB840 PB980 Puritan Bennett Ventilator Machine

Inquiry Cart 0