PHiliph S12-4 Sector Array Transducer 12 - 4 MHz For IE33, IU22, HD 11XE, HD15, HD9 Ultrasound

Brand Name:PHiliph
Model Number:S12-4
Minimum Order Quantity:One piece
Delivery Time:3-5 working days
Payment Terms:T/T, Western Union,Paypal
Packaging Details:Carton
Contact Now

Add to Cart

Verified Supplier
Location: Guangzhou Guangdong China
Address: TianHe District,GuangZhou,GuangDong
Supplier`s last login times: within 33 hours
Product Details Company Profile
Product Details

PHiliphh S12-4 sector array transducer 12 - 4 MHz Used good condition FOR IE33, IU22, HD 11XE, HD 15, HD 9 ultrasound Machine


Specification of PHiliphh S12-4 sector array transducer 12 - 4 MHz


Product NamePHiliphh S12-4 sector array transducer 12 - 4 MHz
BrandPHiliphh
Part NoS12-4
Frequency range12 - 4 MHz
Aperture9.78 mm
Number of elements96
Array TypeSector
Field of view90°
Modes2D, steerable PW Doppler, CW Doppler, High-PRF Doppler, color Doppler, tissue Doppler, advanced XRES, and harmonic imaging
ApplicationsPediatric cardiac and neonatal head applications
Biopsy capableNo

Probe Common Problems


1. Probe wear

After a certain period of use, the surface of the ultrasound probe will gradually wear out, causing poor reflection of the ultrasonic signal and affecting the detection accuracy. If the probe is worn out, it should be replaced or repaired in a timely manner.


Repair method: Remove the probe, clean the residue, wipe the surface with a cloth, and then replace the new probe.


2. Poor contact of the probe line

While an ultrasound probe is in use, its transmission line may disconnect or have poor contact, causing the signal to be lost or the data to not be fully displayed.


Repair method: Check the probe line. If disconnected, the probe line should be soldered or replaced with a new probe line. If poor contact is found, the probe line can be cleaned with alcohol or the line connector replaced.


3. Probe waterproof seal failure

When using an ultrasonic probe, water is needed to transmit ultrasound, which plays the role of transmitting sound waves and sound images. Therefore, the effectiveness of the probe's water seal is crucial to its operational effectiveness. A bad water seal on the probe will affect the transmission of sound waves and the effectiveness of the image, and may even damage the probe.


Maintenance method: First check whether the probe's water seal is good. If not, replace the new water seal or fill it with a sponge. At the same time, it is also necessary to check whether the probe's water tank, water supply pipe and drain pipe are normal to ensure smooth water circulation.


4. Aging of probe parts.

When an ultrasonic probe is used for a long time, the probe parts will age, such as the fatigue of the probe's piezoelectric sheet and the aging of the coil. These problems will affect the transmission of ultrasonic signals and images.


Maintenance method: If the probe parts are aging, it is recommended to replace a new ultrasound probe for maintenance.


Summary: The above is an introduction to the common faults of ultrasound probes and maintenance methods. In the process of using ultrasound probes, faults should be resolved in a timely manner to ensure the normal operation of the probe and the accuracy and effectiveness of detection.



Thank you so much for your attention .If you have any interested in PHiliphh S12-4 Sector Array Transducer 12 - 4 MHz For IE33, IU22, HD 11XE, HD15, HD9 Ultrasound ,feel free to contact us .Thank you .

China PHiliph S12-4 Sector Array Transducer 12 - 4 MHz For  IE33, IU22, HD 11XE, HD15, HD9 Ultrasound supplier

PHiliph S12-4 Sector Array Transducer 12 - 4 MHz For IE33, IU22, HD 11XE, HD15, HD9 Ultrasound