PHiliph C8-4v Curved Array Ultrasound Transducer Probe For hospital

Brand Name:PHiliph
Model Number:C8-4v
Minimum Order Quantity:One piece
Delivery Time:3-5 working days
Payment Terms:T/T, Western Union,Paypal
Packaging Details:Carton
Contact Now

Add to Cart

Verified Supplier
Location: Guangzhou Guangdong China
Address: TianHe District,GuangZhou,GuangDong
Supplier`s last login times: within 33 hours
Product Details Company Profile
Product Details

PHiliphh C8-4v Curved Array Ultrasound Transducer Probe


About PHiliphh C8-4v Curved Array Ultrasound Transducer Probe

The frequency of PHiliphh C8-4v Curved Array Ultrasound Transducer Probe is 8-4 MHZ.

It can be compatible with iU22, HD15, HD11 XE, HD9, HD7 XE, HD7, HD6 and HD5 Ultrasound machine .The features are below :


  • 8 to 4 MHz extended operating frequency range
  • End-fire sector, 11 mm radius of curvature
  • 2D, steerable pulsed wave and color Doppler, M-mode, Color Power Angio, SonoCT, XRES, Panoramic, Freehand 3D and harmonic imaging
  • Endovaginal applications
  • Contrast applications
  • Supports biopsy guide capabilities
  • The PHiliphh C8-4V Curved Array Transducer is compatible with the PHiliphh iU22, HD15, HD11 XE, HD9, HD7 XE, HD7, HD6 and HD5 Ultrasound Systems
  • 4 MHz - 8 MHz

Specification of PHiliphh C8-4v Curved Array Ultrasound Transducer Probe


Product Name

PHiliphh C8-4v Curved Array Ultrasound Transducer Probe


BrandPHiliphh
Model NumberC8-4v
Frequency

4 MHz - 8 MHz


MOQOne piece

Definitions of Cleaning


All PHiliphh transducers require proper care, cleaning, and handling. This section contains information and instructions to help you effectively clean, disinfect, and sterilize transducers for use with PHiliphh ultrasound systems. In addition, these instructions will help you avoid damage during the cleaning, disinfection, and sterilization process that could void your warranty.

Reasonable care includes inspection, cleaning, and disinfection or sterilization when necessary. The transducer must be cleaned after each use. Do not allow contaminants to dry on the transducer. You can use an enzymatic foam spray to remove dried contaminants.

Before each use, carefully inspect all parts of the transducer. Check for cracks or other damage that compromises the integrity of the transducer. If any damage occurs, report it to your authorized service representative and discontinue use of the transducer.


Definitions of Cleaning, Disinfection, and Sterilization of Transducers

All cleaning, disinfection, and sterilization represent a statistical reduction in the number of microorganisms present on a surface, not a complete elimination. Meticulous cleaning of the transducer is key to initially reducing the microbial/organic load by at least 99%. This cleaning should be followed by a disinfection procedure to ensure a high degree of protection against the transmission of infectious diseases (even when a disposable barrier is placed over the transducer during use).



Thank you so much for your attention .If you're interested in PHiliphh C8-4v Curved Array Ultrasound Transducer Probe,feel free to contact us .Thank you .