FUKUDA FC-1760 Defibrillator Paddle Interface Defibrillator Machine Accessories Defibrillator Parts Discharge Equipment

Brand Name:FUKUDA
Model Number:FC-1760
Minimum Order Quantity:1
Delivery Time:3-5 Work Days
Payment Terms:T/T(wire transfer), Western Union, Paypal
BRAND:FUKUDA
Contact Now

Add to Cart

Verified Supplier
Location: Guangzhou Guangdong China
Address: TianHe District,GuangZhou,GuangDong
Supplier`s last login times: within 33 hours
Product Details Company Profile
Product Details

FUKUDA FC-1760 Defibrillator Paddle Interface


Brief Introduction

This is a FUKUDA FC-1760 Defibrillator Paddle Interface, which is used to connect the handle of the defibrillator machine.


Feature

The defibrillator device has two electrode plates with wires, namely the positive and negative electrodes. The specific placement depends on the specific instrument used. The defibrillator is mainly used for patients with cardiac arrest. It uses electric current to shock the heart to terminate ventricular fibrillation. Restore the patient's sinus rhythm. Defibrillators need to be used by personnel with formal medical training. Pay attention to ensuring that irrelevant personnel are kept away before operation. The operator's body should not touch the edge of the bed. Apply conductive glue and keep both arms straight. During the defibrillation process, be sure to press with both hands at the same time. . Common positions include anterolateral and anteroposterior positions. The traditional manual defibrillator electrode pad position can be anterolateral or anteroposterior according to the position of the cardiac arrest patient, while automatic defibrillators generally choose the anterolateral position. The anterior position is also called the standard position and is suitable for emergency defibrillation. The positive plate is placed in the second to third intercostal space on the right edge of the sternum, close to the sternum, but be careful not to overlap the electrode and the sternum. The negative plate is placed in the fifth intercostal space in the left front axillary line and at the apex of the heart. The distance between the positive and negative electrode plates should be greater than 10 cm. When operating in the anteroposterior position, the patient should be on the right side, with the positive plate placed on the left edge of the sternum between the third and fourth intercostals, and the negative plate placed on the left side of the back under the scapula.


Parameters

BRANDFUKUDA
PRODUCT NAMEDefibrillator Paddle Interface
WARRANTY90 Days
CONDITIONIn Good Working Order
MATERIALPlastic/Metal/Wire
COLORWhite/Black
MOQOne Piece
IN STOCKYes
MODELFC-1760

Company Business

If you have any other questions about this product, you can contact us to answer your questions. In addition, if you want to know more about monitors, electrocardiographs, defibrillators, ventilators and accessories for various medical equipment and machines, you can contact us. We are mainly engaged in medical equipment and medical machine accessories. .

Regarding the after-sales issues of the goods, our warranty is 90 days. The goods will be carefully inspected and packaged before they are sent out to ensure that you receive satisfactory goods. Check the goods as soon as possible after you receive the goods. If you have any questions, please contact us. Contact us at any time.


Product Details Picture


Thank you for taking the time to pay attention to our FUKUDA FC-1760 Defibrillator Paddle Interface product

China FUKUDA FC-1760 Defibrillator Paddle Interface Defibrillator Machine Accessories Defibrillator Parts Discharge Equipment supplier

FUKUDA FC-1760 Defibrillator Paddle Interface Defibrillator Machine Accessories Defibrillator Parts Discharge Equipment

Inquiry Cart 0