Home /Other Computer Parts /

Philip M3507A Hands Free Pad Connector Cable For M3501A、M3502A、M3503A M3504A Multifunction Defibrillator Pads

Philip M3507A Hands Free Pad Connector Cable For M3501A、M3502A、M3503A M3504A Multifunction Defibrillator Pads

Brand Name:Philip
Model Number:M3507A
Minimum Order Quantity:1
Delivery Time:5-8 work days
Payment Terms:T/T(wire transfer), Western Union, Paypal
BRAND:Philip
Contact Now

Add to Cart

Verified Supplier
Location: Guangzhou Guangdong China
Address: TianHe District,GuangZhou,GuangDong
Supplier`s last login times: within 33 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

Philip M3507A Hands Free Pad Connector Cable For M3501A,M3502A,M3503A M3504A Multifunction Defibrillator Pads


Brief Introduction

Philip M3507A Hands Free Pad Connector is a multifunctional defibrillator pad suitable for M3501A, M3502A, M3503A and M3504A. The length of the hands-free defibrillation patient cable is 9 feet. The material is plastic and the overall color is black. The function of the cable is to transmit power, transmit signals or convert electromagnetic energy. Therefore, cables have a wide range of applications and are of great value.


Feature

The internal material of the cable is copper core wire. Our cable has the characteristics of sterility, low interference, wear resistance, and corrosion resistance to ensure the safety and reliability of the defibrillator. It is mainly used to connect the electrode pads on the defibrillator. The electrode pads are also one of the most important accessories of the defibrillator. Defibrillator is a kind of medical equipment commonly used in hospitals. The specifications of defibrillator include: waveform, biphasic truncation index, adjustment of waveform parameters according to patient impedance, electric shock delivery, through multifunctional defibrillation electrode pads or paddles. Defibrillation is delivered primarily through external or internal defibrillation paddles, or through multifunctional defibrillation electrodes. Monitoring can be performed in AED and manual modes via electrode pads, 3-lead ECG monitoring electrodes, or optional 5-lead ECG monitoring electrodes. Optional pulse oximetry (SpO2) monitoring is also available in AED and manual modes. When monitoring ECG or SpO2, the physician can set heart rate and/or SpO2 alarms to alert the physician when these parameters exceed defined limits. In addition, the defibrillator also needs to perform some regular inspections regularly to ensure that there are no safety hazards in the defibrillator. During routine inspections, the defibrillator must be clean, free of dirt, with objects on top, and no obvious signs of damage. . Paddles/cables/connectors, make sure there are no cracks, broken wires, or other obvious signs of damage, and make sure the connectors are securely engaged.


Clean Electrode Cables

Clean the defibrillation electrode cable as followsAlcohol-free hand sanitizer
2% glutaraldehyde solution (such as Cidex)
10% sodium hypochlorite (chlorine bleach) aqueous solution
Quaternary ammonium compounds (such as Lysol)
Isopropyl alcohol
Caution

Do not ultrasonically clean, soak, autoclave, or steam sterilize electrode pad cables.



Product Details Picture


Thank you for taking the time to pay attention to our Philip M3507A Hands Free Pad Connector Cable For M3501A, M3502A, M3503A M3504A Multifunction Defibrillator Pads product.


China Philip M3507A Hands Free Pad Connector Cable For M3501A、M3502A、M3503A  M3504A Multifunction Defibrillator Pads supplier

Philip M3507A Hands Free Pad Connector Cable For M3501A、M3502A、M3503A M3504A Multifunction Defibrillator Pads

Inquiry Cart 0