Home /Valves /

Hamilton Pediatric & Adult Expiratory Valve Set with cover and membrane REF 161186 for C1 T1 T1 Military MR1 Ventilator

Hamilton Pediatric & Adult Expiratory Valve Set with cover and membrane REF 161186 for C1 T1 T1 Military MR1 Ventilator

Brand Name:Hamilton
Model Number:161186
Minimum Order Quantity:1
Delivery Time:3-5 working days
Payment Terms:T/T, Western Union,PayPal
Product name:Hamilton Expiratory Valve
Contact Now

Add to Cart

Verified Supplier
Location: Guangzhou Guangdong China
Address: TianHe District,GuangZhou,GuangDong
Supplier`s last login times: within 33 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

Hamilton Pediatric & Adult Expiratory Valve Set with cover and membrane REF 161186 for C1 T1 T1 Military MR1 Ventilator machine


► Brief Introduction

The HAMILTON Neonatal Expiratory Valve Set with Cover and Membrane is a medical device used in neonatal ventilation to control the flow of gases during expiration. It includes a valve, cover, and membrane that work together to regulate the release of exhaled air from the patient's lungs. This device is essential for maintaining appropriate levels of carbon dioxide in the blood and ensuring efficient gas exchange in newborn babies who require respiratory support.


► How to use

Open the packaging of the HAMILTON Neonatal Expiratory Valve Set and remove the contents.

Insert the membrane into the cover by aligning the holes in the center of the membrane with the corresponding pegs on the cover. The membrane should be securely placed in the cover.

Connect the assembled cover and membrane to the expiratory valve on the neonatal breathing circuit. Ensure that it is securely attached to prevent any leaks during expiration.

Once the valve set is properly connected and in place, turn on the ventilator and set the appropriate settings for the neonatal patient.

Monitor the patient's breathing and adjust the ventilator settings as needed to provide the necessary support.

When the neonatal patient is no longer in need of ventilator support, disconnect the HAMILTON Neonatal Expiratory Valve Set and dispose of it according to the appropriate medical waste disposal guidelines.

Keep records of the usage of the valve set and replace it with a new one as needed to maintain proper and safe respiratory support for neonatal patients.


To assemble/install the expiratory valve set


1. Remove the safety cover.

2. Ensure the membrane is properly aligned with the expiratory valve housing and the metal plate faces up (1).

3. Position the expiratory valve set in the expiratory port (2) and twist the locking ring clockwise until it locks into place (3).

► Brief Introduction

The HAMILTON Neonatal Expiratory Valve Set with Cover and Membrane is a medical device used in neonatal ventilation to control the flow of gases during expiration. It includes a valve, cover, and membrane that work together to regulate the release of exhaled air from the patient's lungs. This device is essential for maintaining appropriate levels of carbon dioxide in the blood and ensuring efficient gas exchange in newborn babies who require respiratory support.


► How to use

Open the packaging of the HAMILTON Neonatal Expiratory Valve Set and remove the contents.

Insert the membrane into the cover by aligning the holes in the center of the membrane with the corresponding pegs on the cover. The membrane should be securely placed in the cover.

Connect the assembled cover and membrane to the expiratory valve on the neonatal breathing circuit. Ensure that it is securely attached to prevent any leaks during expiration.

Once the valve set is properly connected and in place, turn on the ventilator and set the appropriate settings for the neonatal patient.

Monitor the patient's breathing and adjust the ventilator settings as needed to provide the necessary support.

When the neonatal patient is no longer in need of ventilator support, disconnect the HAMILTON Neonatal Expiratory Valve Set and dispose of it according to the appropriate medical waste disposal guidelines.

Keep records of the usage of the valve set and replace it with a new one as needed to maintain proper and safe respiratory support for neonatal patients.


To assemble/install the expiratory valve set

1. Remove the safety cover.

2. Ensure the membrane is properly aligned with the expiratory valve housing and the metal plate faces up (1).

3. Position the expiratory valve set in the expiratory port (2) and twist the locking ring clockwise until it locks into place (3).


► To disassemble and remove the expiratory valve set

1. Remove the expiratory valve set from the expiratory port on the ventilator.

2. Holding the expiratory valve housing, remove the silicone membrane (1) by lifting it up.


► Specification

Patient data / ComponentAdultPediatric
Patient height (cm)> 13030 to 150
IBW (kg)> 303 to 48
Tracheal tube ID (mm)> 4
Breathing circuit limb ID (mm)15 to 2210 to 22
Flow sensorAdult/PedAdult/Ped
CO2 airway adapterAdult/PedAdult/Ped



Thank you for your time and interest in Hamilton Pediatric & Adult Expiratory Valve Set with cover and membrane REF 161186 for C1 T1 T1 Military MR1 Ventilator .

"Quality assurance" is our eternal pursuit and promise. Don't be hesitant to contact us! Welcome to place your orders.

China Hamilton Pediatric & Adult Expiratory Valve Set with cover and membrane REF 161186 for C1 T1 T1 Military MR1 Ventilator supplier

Hamilton Pediatric & Adult Expiratory Valve Set with cover and membrane REF 161186 for C1 T1 T1 Military MR1 Ventilator

Inquiry Cart 0