Add to Cart
This keyboard film is suitable for GE B30 monitor machines. Do not let liquid enter the key film. Do not let any liquid stay on the surface of the device. Absolutely do not use abrasive materials and bleach. It is recommended to use a clean cloth. When cleaning the outer surface, cut off the power supply of the monitor first if possible. You can use 70% ethanol or neutral soapy water to clean the outer surface. Do not use strong solvents trichlorethylene; use a soft cloth to clean the outer surface, especially the screen. .
☑Chemical, abrasion and scratch-resistant front panel
☑Button letterpress printing
☑Sturdy plastic housing
☑Integrated 38mm trackball
☑Resistant to dirt, dust and liquids (IP65)
☑CE, FCC certification
☑Short travel key
Check the equipment and accessories by performing the following functional tests monthly. Check for cleanliness and physical damage; check cables and wires. Determine if there is physical damage. After connecting the monitor, pull the patient cable to confirm whether there is an intermittent fault;
1. Compare the distance between each hole in the gold moon plate.
Fix the emblem-shaped switch on the printing plate, and connect the
connecting wire according to the corresponding connecting point of
each switch. At the same time, according to the actual space
between the metal plate and the display board, leave the
corresponding printing plate edge to fix the switch board. Since
the new switch board is between the metal plate and the indicator
light display board, the printing plate must also have holes
corresponding to the indicator light position 2 of the display
board. This is to ensure that the luminous tube of the display
board passes through the printed board and the display signal can
be seen from the panel. There must be a certain distance between
the line and the two boards to prevent short circuit;
2. Embed the printed switch board in the small hole corresponding
to the metal plate of each button switch, so that the top of the
button column is parallel to the metal plate surface. If it is too
high beyond the plate surface, the outer layer After the panel film
is restored, the switch will be pressed down and cannot be used. If
it is too low, the switch will not be in place and will not work
when pressed by hand. After embedding the broken switch plate, use
a rubber pad to flatten it before use. The left glue is attached to
the metal plate, and finally the outer protective film of the panel
is restored to its original position. The modification process is
completed. The modified switch plate has a very good operating
feel. . There is a clear shrapnel sound when the keys are pressed,
giving people a very intuitive on-off feeling. It has a long
service life, high reliability and easy maintenance. If there is a
problem with a certain switch during use, you can directly judge
and replace it by the sound of the shrapnel of the membrane switch
button.
Model | B30 Patient Monitor Keypad Membrane PN M1002328 |
certification | CE |
LATEX | NO |
Material | ABS |
Size | 5*12cm |
Warranty | 90 days |
Condition | Good |