GE Carescape B850 Patient Monitor Power Supply Board PN 10020491 MODEL GCS350PS15
GE Carescape B850 Patient Monitor Power Supply Board PN 10020491 MODEL GCS350PS15 Brief Introduction
The monitor power board is an electronic device that provides power to the entire monitor instrument. Its main function is to convert, adjust and stabilize the input power to meet the different needs of the monitor instrument for electrical energy. The monitor power board plays a vital role in the monitor. Without the power board, the monitor cannot work properly.
Feature
The function of the monitor power board is to convert the input power into the power required by the monitor. The important thing is to convert ordinary alternating current into the required direct current. Its working principle is based on capacitance and inductance to store energy during the switching cycle. Release to adjust the output voltage to achieve voltage stabilization. The monitor power board needs to input different power voltages to the module boards in each monitor instrument to ensure that other parts can operate normally. For example, the power requirement for the CPU in the monitor machine is 100 to 240VAC, 50-60Hz. The monitor power board is also a transformer in the monitor. When AC power is input to the power board, the input voltage will be converted into low-voltage AC power in a certain proportion. After the rectification process by the rectifier, DC power is generated, and then filtered by the capacitor to eliminate residual clutter, allowing the monitor to obtain a more stable DC output voltage.
If the power board encounters liquid, the power board may be damaged, and in serious cases it may affect the function of the entire machine. Therefore, if liquid accidentally enters the inside of the machine, please disconnect the power supply immediately and perform maintenance on the equipment.
General Instructions For Cleaning Parts
Cleaning instructions | Power off the device. |
Disconnect power from the device. | |
Remove all cables and battery (if applicable) and close the battery door. | |
Dampen a soft, lint-free cloth with an approved cleaner or disinfectant. | |
Wring excess liquid from the cloth and wipe the exterior surfaces. Any contact of the disinfectant solution with metal parts may cause corrosion. Do not damage or bend connector pins when cleaning or drying. | |
Allow the solution to remain on the device for at least one minute. Do not allow fluid to accumulate around the connecting pin. If this happens, blot it dry with cotton Cotton swab or soft cloth. | |
Wipe off the cleaning solution with a clean, slightly damp cloth. | |
Dry thoroughly with a dry, lint-free cloth and allow to air dry for at least 30 minutes. Drying time may vary depending on environmental conditions. |