Home /Other Computer Accessories /

Mindary BeneVision N17 Patient Monitor parts Alarm LED Bulb And Light Board 050-002275-01

Mindary BeneVision N17 Patient Monitor parts Alarm LED Bulb And Light Board 050-002275-01

Brand Name:Mindray
Model Number:050-002275-01
Minimum Order Quantity:1pcs
Delivery Time:3-5 working days
Payment Terms:T/T(wire transfer), Western Union, Paypal
Packaging Details:Carton
Contact Now

Add to Cart

Verified Supplier
Location: Guangzhou Guangdong China
Address: TianHe District,GuangZhou,GuangDong
Supplier`s last login times: within 33 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

050-002275-01 Mindary BeneVision N17 Patient Monitor Alarm LED Bulb and Light Board


Alarm LAMP Board

Alarm LAMP Board board is equipped with LED alarm light and light sensor. The light sensor detects the ambient light and adjusts the brightness


of the background light of the LCD.


Alarm Failures


Failure DescriptionPossible CauseTroubleshooting
Alarm LED goes off or fails to turn off when audible alarm soundsCable defective or improperly connected

n1. Check whether the cable connecting the alarm light board and the main control board is connected correctly. n

2. Confirm that the connecting cables and connectors are not damaged

Alarm LED board failureReplace the alarm LED board.
Main control board failureReplace the main control board.
There is no audible alarm when the alarm LED is normalAudible alarm disabledSelect the Main Menu quick key, from the System column, select Maintenance → enter required password → select Alarm, set Minimum Alarm Volume to a proper value. Select the Main Menu quick key, from the Alarm column, select Setup, adjust the alarm volume to a proper value.
Speaker failureReplace the speaker.
Cable defective or improperly connectedVerify the cable connecting the speaker to the main control board is properly connected.
Main control board failureReplace the main control board.

Removing the Alarm Lamp and Light Sensor Board


1. Remove the cable on the alarm lamp and light sensor board.


2. Remove the two PT3×8 screws and take out the alarm lamp and light sensor board


NOTE

  • Be careful when disconnecting the cable to avoid damage.
  • When installing, align the positioning ribs of the front shell plate, and press the plate towards the direction of the alarm light cover.
  • When reinstalling the board, be careful to avoid overtightening the screws and stripping the holes.

Alarm category


The monitor has two different types of alarms: physiological alarms and technical alarms.


■ Physiological alarms are triggered by patient measurements that exceed parameter limits or patient conditions that are abnormal.


■ Technical alarms are triggered by failure of electrical, mechanical or other monitors, or failure of sensors or components. A technical alarm condition may also result when the algorithm is unable to classify or interpret the available data. In addition to physiological and technical alarms, information can be prompted to inform the status of the system or the status of the patient.


Adjusting the Alarm Light Brightness


NOTE:

If you set alarm light brightness to Auto, the monitor automatically adjusts the alarm light brightness according to the ambient light. The stronger


the ambient light is, the brighter the alarm light is.



Thank you so much for your attention .If you're interested in 050-002275-01 Mindary BeneVision N17 Patient Monitor Alarm LED Bulb and Light Board,feel free to contact us .Thank you .

China Mindary BeneVision N17 Patient Monitor parts Alarm LED Bulb And Light Board 050-002275-01 supplier

Mindary BeneVision N17 Patient Monitor parts Alarm LED Bulb And Light Board 050-002275-01

Inquiry Cart 0