GE Dash1800 Dash2500 Patient Monitor Parts Parameter Module DAS Board Assembly Masima And Necllor

Brand Name:GE
Minimum Order Quantity:1
Delivery Time:3-5 working days
Payment Terms:T/T, Western Union,PayPal
Product name:GE DAS Board assembly
Type:DAS Board assembly
Contact Now

Add to Cart

Verified Supplier
Location: Guangzhou Guangdong China
Address: TianHe District,GuangZhou,GuangDong
Supplier`s last login times: within 33 hours
Product Details Company Profile
Product Details

GE Dash1800 Dash2500 patient monitor parameter DAS module DAS Board assembly Masima and Necllor


► Brief Introduction

The DAS assembly is a field replaceable unit only. There are NO field repairs or adjustments for the DAS assembly. Please Do NOT open the DAS assembly as this breaks the isolation barrier which may result in patient death or serious injury.


► Replace DAS Board Assembly

1. Remove the recorder assembly first.

2. Remove the four screws from the rear case assembly and take out the chassis assembly.

3. Pull out the DAS assembly and replace with the new DAS assembly. There are two DAS assemblies to select: DAS assembly with Nellcorrr ® SpO2 or DAS assembly with Masima® SpO2.


Functional tests:


1. SpO2: The SpO2 sensor used depends on the screen configuration.

Nellcorrr® —SpO2 screens use a two-part assembly: DS-100A and NELL1 GE.

Masima SET screens® --SpO2 use a set of interface cable and sensor.

Connect the cables before connecting them to the screen. The SpO2 reading is displayed within moments of connecting the sensor to either the SpO2 simulator or your finger.

2. Blood pressure: A blood pressure test is performed by connecting the hose and belt attached together, and then connecting them to the NIBP connector on the left side of the screen. Press the NIBP Go/Stop hard key in the foreground to start the NIBP cycle.

3. ECG: Electrocardiogram monitoring uses the formation of 3 electrodes or 5 electrodes.

3-Lead ECG connection - Connect the ECG lead connector to the ECG box cable before connecting it to the screen. The simplest way to test the functions of an electrocardiogram circuit is through the use of an electrocardiogram simulator.

5-Lead ECG connection - Connect the ECG lead connector to the ECG box cable before connecting it to the screen. The simplest way to test the functions of an electrocardiogram circuit is through the use of an electrocardiogram simulator.

4. Temperature: Connect the temperature probe with a device

Interview connection. The predictive temperature begins as soon as the probe is removed from the clipboard. Replace the sensor after the TEMP cycle is finished.


Nellcorrr SpO2

Range20 to 250 bpm
Accuracy and tolerance20 to 250 bpm ± 3 digits
Low perfusion20 to 250 bpm ± 3 digits

Measurement rangeSpO21 to 100%
Pulse rate20 to 250 bpm

Masima SpO2


Range25 to 240 bpm
Accuracy and motion tolerance Without motion25 to 240 bpm ± 3 digits
Accuracy and motion tolerance With motionnormal PHiliphhilipysiologic range, 25 to 240 bpm ± 5 digits
Measurement rangeSpO21 to 100%
Pulse rate25 to 240 bpm

Please kindly contact us, if you are interested in GE Dash1800 Dash2500 patient monitor parameter DAS module DAS Board assembly Masima and Necllor, Thank you!


China GE Dash1800 Dash2500 Patient Monitor Parts Parameter Module DAS Board Assembly Masima And Necllor supplier

GE Dash1800 Dash2500 Patient Monitor Parts Parameter Module DAS Board Assembly Masima And Necllor