Med-tronic PHiliphhilipYSIO CONTROL LIFEPAK CR Plus Defibrillator Equipment


Brief Introduction

The Lifepak CR Plus defibrillator is an automatic external defibrillator (AED). Over the years, defibrillators have been used only by health professionals to treat victims of sudden cardiac arrest (SCA). Today, the ability of life-saving defibrillators is so widely recognized that people who were once trained to perform cardiopulmonary resuscitation (CPR) alone can now use defibrillators.
After the electrode pad is applied to the chest of the victim, the defibrillator analyzes the rhythm of the victim's heart. When a shock able rhythm is detected, the defibrillator sends a strong electric pulse (shock) to the myocardium (fully automatic model) or tells the responder to shock (semi-automatic model). The defibrillator shock the victim through an electrode pad in the chest.
When this electrical pulse is supplied, it is called defibrillation. Defibrillation is recognized to treat life-threatening heart rhythm irregularities such as ventricular fibrillation causing SCA.
The Lifepak CR Plus is specifically designed for use by people with low frequency of use and trained only in the use of CPR and AED.


Indications of use
The Lifepak CRPlus defibrillators have been shown to be used in patients with cardiac arrest. The patient should be unresponsive (unconscious), not breathing normally and without signs of circulation (e.g., pulse, cough, no movement). With low energy defibrillation electrodes for infants, the LIFEPAK CR Plus defibrillator can be used for children up to 8 years old or up to 25 kg (55 LBS) in weight.


Inside Features

Quick reference cardThis card provides abbreviated graPHiliphhilipic directions for using your defibrillator to treat a victim in cardiac arrest.
Use By dateUse By date shown (yyyy-mm-dd) can be viewed through the defibrillator lid when it is closed
Electrode packetThe QUIK-PAK electrode packet is preconnected to the defibrillator.
This packet contains a set of electrode pads.
Electrode packet release handleWhen you pull this handle, the electrode packet tears open.
Electrode packet anchor pinThis pin securely positions the electrode packet to the defibrillator.

Controls, Indicators, and Labels


Operating Settings

Device IDDevice ID is a unique identifier (ID) assigned to each defibrillator used for tracking the location of defibrillators. If you have multiple defibrillators at
your location, you should give each a unique name, such as Building 1, Building 2, and so on. When you transfer event data from the defibrillator to a PC, the defibrillator ID will be included in the transferred data
Energy SequenceEnergy sequence defines the energy levels used by the defibrillator.
The energy level choices are: 150, 175, 200, 225, 250, 275, 300, 325, 360
Level 1 – 200 joules
Level 2 – 300 joules
Level 3 – 360 joules
CPR Time 1
CPR Time 2
The CPR Time 1 and CPR Time 2 settings define
the time interval for performing CPR after a shock
or after a no shock advised decision.
The choices for CPR Time 1 and CPR Time 2 are
15, 30, 45, 60, 90, 120, and 180 seconds.
CPR Time 1–120 sec
CPR Time 2–120 sec
Pulse PromptThe pulse prompt setting determines whether the defibrillator prompts you to check the victim’s pulse (appropriate for medically trained users) or to check the victim for signs of circulation such as breathing and movement (appropriate for lay users). Choices are Check Pulse, Check Breathing, or Check Circulation.
Stack ShocksWhen set to OFF, the Stack Shocks option eliminates the analysis after each shock and inserts prompting for CPR after each (a single) shock. This eliminates the three-shock stack. CPR is prompted regardless of the ECG rhythm after the shock. The CPR time following the shock is determined by the CPR Time 1 setting selected. Choices for Stack Shocks option are ON or OFF.
When set to ON, an analysis will occur after shocks, and up to three shocks in a row may be delivered (three-shock stack).
Pulse CheckWhen set to Never, the Pulse Check option removes all prompting for pulse checks. The other Pulse Check settings available allow pulse checks
only after every No Shock Advised (NSA) decision, after the second NSA decision and thereafter, or Always (after shocks, NSA and CPR).
Motion DetectionThe motion detection setting is used to determine if motion detection is active or not active during analysis.
When motion detection is On, the defibrillator stops analysis for up to 10 seconds if it detects any victim motion. The defibrillator notifies the responder of the problem. The defibrillator will resume analysis after 10 seconds, even if motion is still present.
When motion detection is Off, analysis is not inhibited, regardless of any victim motion.