GE Invasive Pressure IP Adapter Cable IBP Tram 451 Dual Adaptor 0.3 Meter REF 2005772-001

GE Invasive Pressure IP Adapter Cable IBP Tram 451 Dual Adaptor 0.3 Meter REF 2005772-001

Brand Name:GE IP Adapter cable
Model Number:TS-F1-H2005772-001
Minimum Order Quantity:1
Delivery Time:3-5 working days
Payment Terms:T/T, Western Union,PayPal
Product name:GE IP Adapter cable
Contact Now

Add to Cart

Verified Supplier
Location: Guangzhou Guangdong China
Address: TianHe District,GuangZhou,GuangDong
Supplier`s last login times: within 33 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

GE Invasive Pressure IP Adapter cable IBP Tram 451 Dual Adaptor 0.3 Meter REF 2005772-001


► Brief Introduction

The dual invasive blood pressure adapter is intended to be used for connection two invasive blood pressure transducers to GE Medical System Information.

Work for GE B20 B20i B40 B105 B125 Modules. Cath-Lab, MAC-Lab, Dash 1000, Dash 2000, Dash 3000, Dash 3100, Dash 4000, Dash 5000, Eagle, Solar 7000, Solar 8000, Solar 9000, Tram 451, Tram Module 100-600, Tram Rac 3, Tram Rac 4A, Tram Scope 100-800 A, Tram Scope 100-800 L

To measure invasive blood pressure, a catheter is inserted into an artery or vein. The invasive pressure setup, consisting of a connecting tubing, a pressure transducer, an intravenous bag of normal saline, all connected together by stopcocks, is attached to the catheter. The transducer is placed at the same level with the heart, and is electrically zeroed.

The transducer is a piezo-resistive device that converts the pressure signal to a voltage. The monitor interprets the voltage signal so that pressure data and pressure waveforms can be displayed.


Invasive blood pressure measurement

Configure the simulator’s IBP channels as follows:

Sensitivity: 5 µV/V/mmHg

InvBP outputs: "0 mmHg static pressure" or "atmosphere"

  • Zeroing
  • Press IBP Zero All key.
  • Check that a message "Zeroing" followed by a message "Zeroed" is shown in the IBP parameter window.
  • Static Pressure
  • Configure the simulator's InvBP output to "200 mmHg static pressure".
  • Check that the flat pressure line appears on the related waveform field. The reading in the parameter window shall be 200 ±10 mmHg.

NOTE: Recalibration is required, if the measured value is not within the specification.

  • Pressure Waveforms
  • Configure the simulator's InvBP output to "Arterial 120/80".
  • Check that the pressure waveform for tested invasive pressure channel appears in the IBP waveform field and the Sys/Dia (Mean) pressure values are shown in the related parameter window.

► Invasive blood pressure connectors (IBP1, IBP2)

1BP_+VREFBP transducer excitation voltage, channel 1
2BP SIG+BP transducer signal positive (+), channel 1
3BP_+VREFBP transducer excitation voltage, channel 2
4AGNDAnalog ground
5BP SIG+BP transducer signal positive (+), channel 2
6SHIELDBP cable shield
7AGNDAnalog ground
8BP SIG1BP transducer signal negative (-), channel 1
9BP SIG2BP transducer signal negative (-), channel 2
10BP1_IDBP1 probe identification
11NCNot connected