Inspired VHC-25 VHC25 Patient Monitor Accessories Reusable Newborn Automatic Humidification Chamber

Brand Name:Inspired
Model Number:VHC-25
Minimum Order Quantity:1pcs
Payment Terms:T/T(wire transfer), Western Union, Paypal
Packaging Details:Carton
Product Name:Inspired VHC-25 VHC25 Reusable Humidification Chamber
Contact Now

Add to Cart

Verified Supplier
Location: Guangzhou Guangdong China
Address: TianHe District,GuangZhou,GuangDong
Supplier`s last login times: within 33 hours
Product Details Company Profile
Product Details

Inspired VHC-25 VHC25 Reusable Newborn Automatic Humidification Chamber


Inspired VHC-25 humidification chamber Specification

TypeReusable
ApplicationAdult
Fill water modeManually
Compressible Volume(empty)695ml
Compressible Volume(full)265ml
Maximum Water capacity430ml
Maximum Peak Flow90L/Min
Resistance (cmH2O)<1CMh2O @60L/Min
Compliance (Empty)<0.85 ml/cmH2O
Package12 pcs/carton

Installing the VHB10A humidifier and chamber.

  • Using the accessories supplied with the device Installation.
  • Check that the humidifier is clean and dry.
  • Fill the cavity with sterilized water up to the water level

The maximum water level marked on the room. Please read the cavity description for detailed information on how to use the cavity.

  • Push the humidifier into the humidifier opening, then use the humidifier to press the button on the top of the humidifier until the button clicks back, indicating that the humidifier is securely attached.

  • Connect the supplied air breathing tube to the chamber inlet.
  • Connect the inspiratory branch to the chamber outlet

  • Connect the temperature monitoring device (thermometer, temperature sensor, etc.) to the patient end of the inspiratory limb.


  • Turn on the fan or air supply.
  • Connect the power cord to a properly grounded outlet and the power supply must have the power rating specified in this manual. The humidifier and the chamber are ready.

Before use, if you have any questions about using the humidifier Please contact Vincent Medical Mfg. Company, Ltd. or your local area support.

The VHB10A is designed to be used for air supply such as the iVent 201 or other fans that meet the requirements of IEC 60601-1 and IEC 60601-1-2.

The following additional accessories are required: Humidification Chamber (e.g. VHC20), breathing circuit (e.g. 51003200).


warns:

Do not immerse the humidifier in liquids.

warns:

1) When installing the chamber, make sure the humidifier and chamber are lower than the patient.

2) When using a humidifier, if the chamber is tilted at an angle greater than the maximum allowable angle, the water in the chamber can flow directly into the patient's breathing circuit or air supply unit.

3) Do not add more water than the maximum level indicated on the humidifier.

4) Before turning on the humidifier, make sure that air is flowing through the chamber and the breathing circuit.

5) Do not use the device with flammable anesthetic gas, otherwise it may cause an explosion.

6) Use the device only with the humidification chamber and air tubing recommended by the manufacturer of Vincent Medical Manufacturing Co., Ltd.


If you're interested in Inspired VHC-25 VHC25 Reusable Humidification Chamber ,feel free to contact us .Thank you .

China Inspired VHC-25 VHC25 Patient Monitor Accessories Reusable Newborn Automatic Humidification Chamber supplier

Inspired VHC-25 VHC25 Patient Monitor Accessories Reusable Newborn Automatic Humidification Chamber

Inquiry Cart 0