BJ-901D Nihon Kohden EKG ECG Cable 10 Leads Wires 15 Pins Needle European Standard Connector

Brand Name:Nihon Kohden
Model Number:BJ-901D
Minimum Order Quantity:1pcs
Delivery Time:3-5 working days
Payment Terms:T/T(wire transfer), Western Union, Paypal
Packaging Details:Carton
Contact Now

Add to Cart

Verified Supplier
Location: Guangzhou Guangdong China
Address: TianHe District,GuangZhou,GuangDong
Supplier`s last login times: within 33 hours
Product Details Company Profile
Product Details

BJ-901D Nihon Kohden EKG ECG Cable 10 Leads Wires 15 Pins Needle European Standard Connector


BJ-901D Nihon Kohden EKG ECG Cable 10 Leads Wires 15 Pins Needle European Standard Connector is an induction wire that can measure standard 12 induction ECG by connecting the chip terminal to the electrode and connecting the connector to the ECG machine


Cable length (electrocardiograPHiliphhilip connection connector - between branches): 2000mm

Limb lead L, R length (branch - chip terminal): 1200mm

Length of limb leads F, N (branch-chip terminal): 1400mm

Chest Lead Length (Branch - Chip Terminal): 700mm

Chip diameter: &PHiliphhilipi;3mm


Lead Cable Diameter3mm
Lead Cable Length Limb1.2mm
Lead Cable Length70mm
Lead Cable MaterialTPU Jacket.
Lead Color CodingIEC
Lead Number10
Patient SizeAdult/Pediatric.
Trunk Cable Length2.2M
Trunk Cable ColorGray
Packaging UnitsOne piece

1. Purpose of use

It is a device that transmits the patient's electrocardiogram signal to an electrocardiograPHiliphhilip (ECG). This product uses electrodes attached to the chest in a pattern.

1. How to use

For the usage of this product, please refer to the instruction manual of the equipment used, such as the electrode and the connection method with the equipment.

(1) Connect the connector of this product to the electrocardiograPHiliphhilip.

(2) Connect electrodes, etc. to the chip terminals of the connected induction wires.

(3) The connected electrodes and the like are attached to the subject according to the pattern.

(4) Measure the ECG with the connected ECG machine.


2. Applicable machine type


ECG-1150,ECG-1250,ECG-1350,ECG-2320,ECG-2150


3. Precautions for use, etc.

(1) Do not use this product except for the purpose of measuring electrocardiogram. The safety of this product and mounting parts (including electrodes) depends on the performance of the connected electrocardiograPHiliphhilip. Use on an unsuitable ECG machine may result in electric shock to the patient.

(2) When using this product, avoid contact with liquid medicine and water, and do not use it in a wet state.

(3) Do not pull the leads and chip terminals with force, and do not bend them forcibly. lead to fracture and lead disconnection.

(4) Please observe the following environmental conditions when using and storing this product.


1) Use environmental conditions

①Temperature range: 5~40℃

②Humidity range: 25~95% (non-condensing)

③Air pressure range :700~1060hPa

2) Save the environmental conditions

①Temperature range :-20~65℃

②Humidity range: 10~95%

③Air pressure range :700~1060hPa


Maintenance and Inspection

1. Cleaning, disinfection and sterilization

(1) Cleaning This product should be cleaned regularly. Wipe with a soft cloth such as water, neutral detergent diluted with water or ethanol for disinfection (conforms to the standard of Japanese PHiliphhiliparmacopoeia. Concentration: 76.9~81.4 vol% of ethanol at 15°C), etc. It is sufficiently dry. If Caruggio cream is used to dry or keep the chip terminals wet, a correct ECG will not be recorded.


(2) Disinfection: Wipe it with a soft cloth containing one of the following disinfectants, then wipe it with a dry cloth to make it fully dry.

• Glutaraldehyde (androstine®, Cydex®, etc.) ..2%

• Alkyldiaminoacetylglycine hydrochloride (Taigao 51®, etc.)...0.5%

• Benzalkonium Chloride (Osban® etc.)...0.2%

• Benzalkonium Chloride (High Amine®, etc.)...0.2%

• Chlorhexidine Gluconate (Xibiteng®, etc.)...0.5% The logos marked with ® are trademarks of the respective companies. (3) Sterilization This product cannot be sterilized.

(4) Precautions for cleaning, disinfection and sterilization

1) Do not soak the connector part with liquid.

2) The connector part, please wipe from only. If water enters the inside, it will cause malfunction.

3) Do not use organic solvents such as thinner, volatile oil, industrial alcohol, etc., otherwise the surface finish will be damaged.

4) When using flammable cleaning and disinfectant such as ethanol, please avoid using it in a closed place and use it with sufficient ventilation.

5) Do not use hypochlorous acid for disinfection.

2. Replacement and disposal

(1) When the lead wire of the replacement electrode is broken, please replace it with a new one.

(2) When disposing of, please dispose of in accordance with the standards of each local government or facility. When disposing of potentially infected products, please follow the standards of each local government or facility. Incorrect disposal may cause infection and environmental impact.


If you're interested in BJ-901D Nihon Kohden EKG ECG Cable 10 Leads Wires 15 Pins Needle European Standard Connector ,feel free to contact us .Thank you .

China BJ-901D Nihon Kohden EKG ECG Cable 10 Leads Wires 15 Pins Needle European Standard Connector supplier

BJ-901D Nihon Kohden EKG ECG Cable 10 Leads Wires 15 Pins Needle European Standard Connector

Inquiry Cart 0