Hospital Equipment Fisher & Paykel Heated Respiratory Humidifier MR850AEA


Fisher & Paykel Heated Respiratory Humidifier MR850AEA


►Brief Introduction

The Fisher & Paykel Heated Respiratory Humidifier MR850AEA is used to warm and humidify gases delivered to patients requiring mechanical ventilation, positive-pressure breathing assistance, or other medical gases. Delivery of specified humidification output or generation of an alarm condition.


► Specifications:

Dimensions(without chamber fitted):140 mm x 173 mm x 135 mm
Weight(without chamber fitted):2.8 kg
Mains Supply:115 V~, 60 Hz
Rated Power:220 VA
Heater-plate Output:150 W
Heater-wire Output:22 V~, 2.73 A, 60 W

Operation:


  • Mute Button

The Mute Button silences the Humidifier’s alarm. The duration of an audio pause is 2 minutes.Pushing the Mute Button can reactive the audio alarm. Mute status is shown with a green indicator.

  • Mode Button

This button switches between Invasive and Mask Mode. Mode selection is shown with a green indicator.

  1. Invasive Mode: It for patients with bypassed airways. The system delivers gas as close to body temperature saturated (37 °C, 44 mg/L) as possible.
  2. Mask Mode: It for patients receiving face mask or head-box therapy. The system delivers a comfortable level of humidity.
 Invasive ModeMask Mode
Humidity Performance:≥ 33 mg/L≥ 12 mg/L
Flow Range:≤ 60 L/min≤ 120 L/min
Chamber Outlet Control Temperature Range:35.5 – 42 °C31 – 36 °C
Airway Control Temperature Range:35 – 40 °C28 – 34 °C
Warm-up Time:< 30 minutes< 30 minutes
  • Alarm

Medium Priority Alarm: Signaled by an audible alarm sound and a flashing visual alarm indicator (yellow).
Low Priority Alarm: Signaled by a constantly-lit visual alarm indicator (yellow).

  • Temperature Display

This displays the saturated gas temperature (the lower of the Airway and Chamber Outlet temperatures in °C) delivered to the patient. This display will normally show the Chamber Outlet temperature (around 37 °C for Invasive Mode, and 31 °C for Mask Mode). By pushing and holding the Mute Button for 1 second, the Chamber Outlet temperature then the Airway temperature is displayed. The display will then revert to normal operation.

  • On/Off Button

The Humidifier will turn ON if this button is held down briefly. The Humidifier will always default to Invasive Mode when it is turned on.The button must be held down for more than 1 second to turn the Humidifier OFF. Remove mains plug to completely isolate power from this device.


If you want to explore more details about Fisher & Paykel Heated Respiratory Humidifier MR850AEA , please let us know. Looking forward to receiving your early inquiry.


China MR850AEA Heated Respiratory Humidifier Medical Equipment Fisher Paykel supplier

MR850AEA Heated Respiratory Humidifier Medical Equipment Fisher Paykel

Inquiry Cart 0