Dash 5000 GE Refurbished Used Patient Monitor For Clinic

Brand Name:GE
Certification:CE
Model Number:Dash 5000
Minimum Order Quantity:1pcs
Delivery Time:3-5 working days
Payment Terms:T/T(wire transfer), Western Union, Paypal
Contact Now

Add to Cart

Verified Supplier
Location: Guangzhou Guangdong China
Address: TianHe District,GuangZhou,GuangDong
Supplier`s last login times: within 33 hours
Product Details Company Profile
Product Details

Dash5000 GE Refurbished Used Patient Monitor For Hospital And Clinic


Main features:

① Optimize the monitoring design of all maintenance applications.

②  Advanced algorithms are applicable to all monitoring parameters

③ Fully flexible alarm settings allow individual monitoring

④ Obtain wired or wireless ECG

⑤ Bright bedside warning lights help quickly locate patients in critical situations

⑥ A variety of installation solutions and a wide range of accessories ensure simple and flexible workplace design

⑦ 3 waveform screens to maximize the parameter value and waveform size

⑧ iTouch Pad convenient maintenance area remote control, which can be operated on either side of the bed, direct access to frequently used functions

⑨ Remote viewing via DashPort2 for the best central overview

⑩ CO2 modules and extensions to include additional Rac parameters

⑪ Broad interface options for iConnect solutions

⑫ Mainstream and low lateral flow CO2 measurement options, suitable for neonatal to adult applications


Display

Size12.1”
Disply TypeActive-matrix color LCD
Resolution800 x 600 dpi
Number of traces7 (maximum)
Number of seconds/trace4.9 at 25 mm/sec
Sweep speed6.25, 12.5, 25 mm/sec (with erase bar)

Control

  • TrimKnob® control
  • Five hard keys standard mute alarm, print, NBP run/stop, reset all and power on/off. Dash 5000 added
  • Trending, NBP automatic, admission/discharge, standby and main view
  • Remote control option available

Alarm

  • Category Patient status and system status
  • Priority level 4-crisis, warning, consultation and information
  • Notification sound and visual
  • Set default and personal
  • Silence for 1 minute, only current alarm
  • Pause for 5 minutes in adult ICU mode, and pause for 3 minutes and 5 minutes in neonatal ICU mode,
  • 15 minutes, or permanently pause in OR mode
  • The volume is 70 dB by default. Invasive blood pressure measured at 1 meter
  • Sensor location: artery, femoral artery, pulmonary artery, central vein, right atrium, left atrium, intracranial and special
  • Sensor requirements Excitation voltage: 5 V dc ± 0.1%
  • Sensor output 5 μV/V/mmHg

ECG

• Provide standard leads I, II, III, V, aVR, aVL and aVF

• 3 lead I, II or III

• 5-lead I, II, III, V, AVR, AVL and AVF

• 10-lead I, II, III, AVR, AVL, AVF, VI, V2, V3, V4, V5 and V6

• Simultaneous analysis of leads I, II, III and V (multi-lead mode)

• Potential customers fail to identify failed prospects

• Alarm user-selectable upper and lower heart rate limits


Pulse oximeter

• Monitoring parameters: arterial blood oxygen saturation (SpO2) and periPHiliphhiliperal blood oxygen saturation

Pulse rate (PPR)

• SpO2 range Nellcorrr 1-100%; Massimo 30-100%; GE Ohmeda 30-100%

• PPR range Nellcorrr 20-300 BPM; Masima 25-240 BPM; GE Ohmeda 30-250

• Accuracy The actual accuracy depends on the probe. Please refer to

• Manufacturer's specifications.

• Nellcorrr SpO2 ± 2 digits (70-100% SpO2)

• Masima SpO2 ± 2% adult/child (70-100% SpO2)

• GE Ohmeda SpO2 ± 2% (70-100% SpO2), SpO2 ± 3% for newborns, ≤ 69%

Unspecified

• PPR ± 3 times/minute

• Alarm User-selectable upper and lower limits of SpO2 and PPR

China Dash 5000 GE Refurbished Used Patient Monitor For Clinic supplier

Dash 5000 GE Refurbished Used Patient Monitor For Clinic