High Output High Frequency Power Solar Inverter 3KW ~ 5KW Reverse Control Integrated for home
1. Excellent performance because of an MCU intelligent control
technology .
2.Visualization of operation status of the equipment through
Chinese and English menus, LEDs and an LCD .
3.Solar array, battery common-anode system input and multiple
independent solar array input control .
4.Settable battery protection parameters .
5.Display of the current battery voltage, battery charge current,
internal temperature of the case, total photovoltaic power
generation capacity, total power consumption by the load,
photovoltaic current when each solar array is separately charged .
6.Overall protection: protection an alarm for reverse connection of
the battery poles, battery overcharge, cooling control for interior
of the cabinet (the fan will be started upon 45°C) and back charge
of the battery at night .
7.Function of historical records and password protection .
8.Function of clock display
INVERTER MODEL | 3KW | 5KW |
Rated Output Power | 3KW | 5KW |
Output Voltage Waveform | Pure Sine Wave | |
Output Voltage Regulation | 230Vac±5% | |
Output Frequency | 50Hz | |
Peak Efficiency | 93% | |
Overload Protection | 5s@≥150% load; 10s@110%~150% load | |
Surge Capacity | 2* rated power for 5 seconds | |
Nominal DC Input Voltage | 24Vdc | 48Vdc |
Cold Start Voltage | 23.0Vdc | 46.0Vdc |
Low DC Warning Voltage | ||
@ load < 50% | 23.0Vdc | 46.0Vdc |
@ load ≥ 50% | 22.0Vdc | 44.0Vdc |
Low DC Warning Return Voltage | ||
@ load < 50% | 23.5Vdc | 47.0Vdc |
@ load ≥ 50% | 23.0Vdc | 46.0Vdc |
Low DC Cut-off Voltage | ||
@ load < 50% | 21.5Vdc | 43.0Vdc |
@ load ≥ 50% | 21.0Vdc | 42.0Vdc |
High DC Recovery Voltage | 32Vdc | 62Vdc |
High DC Cut-off Voltage | 33Vdc | 63Vdc |
No Load Power Consumption | <35W |
INVERTER MODEL | 3KW | 5KW |
Input Voltage Waveform | Sinusoidal (utility or generator) | |
Nominal Input Voltage | 230Vac | |
Low Loss Voltage | 170Vac±7V (UPS); | |
90Vac±7V (Appliances) | ||
Low Loss Return Voltage | 180Vac±7V (UPS); | |
100Vac±7V (Appliances) | ||
High Loss Voltage | 280Vac±7V | |
High Loss Return Voltage | 270Vac±7V | |
Max AC Input Voltage | 300Vac | |
Nominal Input Frequency | 50Hz / 60Hz (Auto detection) | |
Low Loss Frequency | 40±1Hz | |
Low Loss Return Frequency | 42±1Hz | |
High Loss Frequency | 65±1Hz | |
High Loss Return Frequency | 63±1Hz | |
Output Short Circuit Protection | Circuit Breaker | |
Efficiency (Line Mode) | >95% ( Rated R load, battery full charged ) | |
Transfer Time | 10ms typical (UPS); | |
20ms typical (Appliances) |