6KVA 4800Watts 220V 110V UPS Power Supply Computer Room UPS Unit

Brand Name:ZGD
Model Number:C6KS
Minimum Order Quantity:1
Delivery Time:10-15 work days
Payment Terms:Western Union, L/C, T/T
Place of Origin:Guangdong, China
Contact Now

Add to Cart

Active Member
Location: Shenzhen China
Address: 708, No.218, Changchun Road, Shangcun Community, Gongming Street, Guangming District, Shenzhen
Supplier`s last login times: within 25 hours
Product Details Company Profile
Product Details

220V 110V High Frequency Uninterruptible Power Supply For Computer Room 6KVA 4800Watts

True double-conversion on line UPS
DSP technology guarantees high performance
Output power factor 0.8
Standard backup UPS and long backup UPS in one integrated unit
Adjustable battery number from 16 pcs to 20 pcs
Adjustable charging current via LCD or software (0.5A~6A)
Wide input voltage range (110-300 VAC)
Wide input voltage range (110-300 VAC)
50Hz/60Hz frequency converter mode
Emergency power off function (EPO)
3-stage extendable charging design for optimized battery performance
Maintenance bypass available
SNMP/USB/RS-232 communications


6K/10K ONLINE UPS SPECIFICATION
MODELGH11- 6K(L)GH11- 10K(L)
PHASE1 phase in / 1 phase out
CAPACITY6000 VA / 4800 W10000 VA / 8000 W
INPUT
Nominal Voltage208/220/230/240VAC
Voltage RangeLow Line Loss110 VAC ± 3% at 50% Load
176 VAC ± 3% at 100% Load
Low Line Comeback120 VAC ± 3% at 50% Load
186 VAC ± 3% at 100% Load
High Line Loss300 VAC ± 3%
High Line Comeback290 VAC ± 3%
Frequency Range46 Hz ~ 54 Hz or 56 Hz ~ 64 Hz
Power Factor≥ 0.99 @ 100% load
OUTPUT
Nominal Voltage208/220/230/240VAC
AC Voltage Regulation± 1%
Frequency Range
(Synchronized Range)
46 Hz ~ 54 Hz or 56 Hz ~ 64 Hz
Frequency Range (Batt. Mode)50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Current Crest Ratio3:1 (max.)
Harmonic Distortion≤ 3 % THD (Linear Load)
≤ 6 % THD (Non-linear Load)
Transfer Time
(Line mode)
Bypass to InverterZero
Inverter to BypassZero
Waveform (Batt. Mode)Pure Sinewave
EFFICIENCY
Line Mode0.890.9
Battery Mode0.880.89
BATTERY
Standard ModelBattery Type12 V / 7 AH12 V / 9 AH
Numbers1616
Typical Recharge Time9 hours recover to 90% capacity
Charging CurrentDefault:1.0 A ± 10%,
Max.:2.0A ± 10%
Default:1.0 A ± 10%,
Max.:2.0A ± 10%
Float Charging Voltage218.4 VDC ± 1%
Long-run ModelBattery TypeDepending on applications
Numbers16-20pcs(adjustable)
Charging CurrentDefault:4.0 A ± 10%,
Max.:6.0A ± 10%
Default:4.0 A ± 10%,
Max.:6.0A ± 10%
Float Charging Voltage273 VDC ± 1% (based on 20 pcs batteries)
INDICATORS
LCD PanelUPS status, Load level, Battery level, Input/Output voltage,
Discharge timer, and Fault conditions
ALARM
Battery ModeSounding every 4 seconds
OverloadSounding twice every second
FaultContinuously sounding
PHYSICAL
Standard ModelDimension369 x 190 x 688442 x 190 x 688
Net Weight (kgs)6175
Long-run ModelDimension369 x 190 x 318442 x 190 x 318
Net Weight (kgs)1218
ENVIRONMENT
Operation Humidity0-95 % RH @ 0- 40°C (non-condensing)
Noise LevelLess than 55dBA @ 1 MeterLess than 58dBA @ 1 Meter
MANAGEMENT
Smart RS-232/USBSupports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8,
Linux, Unix, and MAC
Optional SNMPPower management from SNMP manager and web browser
*Product specifications are subject to change without further notice



China 6KVA 4800Watts 220V 110V UPS Power Supply Computer Room UPS Unit supplier

6KVA 4800Watts 220V 110V UPS Power Supply Computer Room UPS Unit

Inquiry Cart 0