Add to Cart
Double Deck High Temperature Accelerated Aging Test Chamber for Battery Cell and Module
This test chamber series mainly for testing the battery module of Electric-bike, Electric Motorcycles, etc. These series meet the standard compliance of IEC62619, UL2580 and GB31485-2015. Including short circuit, thermal test, drop test and crush test, etc.
Parameters
Modle | BTT-D2-216A | BTT-D2-360A |
Single-layer internal dimensions(MM) | W600xD600xH600 | W1000xD600xH600 |
External Dimensions(MM) | W1340xD1080xH1765 | W1740xD1800xH2000 |
Structure Style | Integral upper and lower two studio structure | |
Temperature Range | Room temperature +10ºC~+150ºC | |
Temperature Fluctuation | ±0.3ºC | |
Temperature Rise Time | RT+10~+100ºC About 10 minutes | |
Temperature Uniformity | ≤±2ºC(no-load, constant temperature state) | |
Observation Window | W300xH300MM, explosion-proof glass with explosion-proof film | |
Cooling Mode | Air-cooled | |
Control Mode | Touch screen programmable control PLC, with USB interface, with RS485 interface can be connected to computer control, special network control software, convenient remote monitoring, data acquisition | |
Inner Box Material | SUS304# mirror stainless steel, thickness 1.0MM, spray Teflon insulation. | |
Outer Box Material | Galvanized plate, powder coating, high temperature plasticization, thickness 1.2MM | |
Power Supply Voltage | AC380V 50HZ 9KW | |
Safety Protection | Automatic explosion-proof pressure relief device, explosion-proof chain, light alarm device, remote control, smoke exhaust device, fire extinguishing device, etc. | |
Lead Hole | Φ100MM, one on each side, with soft silicone plug and stainless steel cover | |
Expanded Functions | Open communication protocol and charging and discharging machine supporting use |