Thermal Abuse SUS304 220V Battery Test Chambers with Explosion Proof Lock And Chain

Brand Name:DGBELL
Certification:CE/ISO
Model Number:BE-101-1000D
Minimum Order Quantity:1 Set
Delivery Time:Negotiation
Payment Terms:Western Union, T/T, D/P, D/A, L/C
Contact Now

Add to Cart

Active Member
Location: Dongguan Guangdong China
Address: No.11 Wusong 1st Street, Dongcheng District, Dongguan 523117, Guangdong, China
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details

Battery Thermal Abuse Test Chamber IEC 62133-2017 With Explosion-Proof Lock and Explosion-Proof Chain


Thermal abuse test chamber is suitable for standard

  • IEC 62133-2017
  • UL 1642
  • GB 31241-2014

Main technical parameters

Model


BE-101-1000D

Structure


Door with explosion-proof lock + explosion-proof chain
Temperature rangeRoom temperature ~ 200 ℃ within the adjustable control

Control accuracy


±0.5℃

Temperature deviation


±2.0℃, no load
Temperature rise rateRT ~ 150 ℃ (5 ℃ / min, linear load)
Temperature overshoot: ≤2℃

Control display


PLC touch (7 inches) + remote control, networkable, cell phone APP alarm device, with USB interface, with R485 interface can be connected to computer control.

Working cabinet size


W600XD500XH600mm

External dimensions


W940XD780XH1620mm
Inner chamber materialSUS304 stainless steel, mirror finish
Outer chamber materialSECC steel plate, fine powder coating coating
BottomWith universal wheels

Observation window


390X360mm (20mm thick tempered explosion-proof glass)
Power supply voltage220V/50HZ

Heating power


About 12KW
Safety protection deviceWith protection functions such as over-voltage, overheating, over-current and short circuit caused by testers' misoperation Protection of battery electrode positive and negative connection, etc.

Safety devices


Salt spray discharge system, explosion-proof pressure relief port, alarm light

The heating test of battery thermal abuse test chamber shall be carried out as follows


1.Relevant Standard Test Requirements


Single battery safety test

The heating test is carried out as follows:

  • The single battery is charged according to the method of 6.1.3
  • Put the single battery into the temperature chamber.
  • For lithium-ion batteries, the temperature chamber is increased from room temperature to 130 ° C ± 2 ° C at a rate of 5 ° C / min, and the heating is stopped after maintaining the temperature for 30 minutes.
  • For nickel metal cyanide batteries, the temperature chamber is raised from room temperature to 85 ° C ± 2 ° C at a rate of 5 ° C / min, and the heating is stopped after maintaining this temperature for 2h.
  • Observe for 1h.

2.Battery Module Safety Test


1) The battery module battery shall be charged according to the method in 6.1.4.​


2) For lithium-ion batteries, the temperature chamber is raised from room temperature to 130 ° C ± 2 ° C at a rate of 5 ° C / min, and the heating is stopped after maintaining this temperature for 30 minutes.


3) For nickel metal cyanide batteries, the temperature chamber is raised to 85 ° C ± 2 ° C at room temperature at a rate of 5 ° C / min, and the heating is stopped after maintaining this temperature for 2h.


4) Observe for 1h.

China Thermal Abuse SUS304 220V Battery Test Chambers with Explosion Proof Lock And Chain supplier

Thermal Abuse SUS304 220V Battery Test Chambers with Explosion Proof Lock And Chain

Inquiry Cart 0