Laboratory Battery External Short Circuit Current Test Machine According to UL 2580


Relevant standards requirement


1. Test object: battery pack and system


2. Test conditions:

  • The test temperature should be at 20±10ºCor higher. (According to the battery system manufacturer's request).
  • All protective devices that affect the function of the test objects and related to the test results shall be in normal operation when the test starts.

3. The main contactors used for charging and discharging should be closed to indicate the feasible vehicle mode and the mode of allowing external charging. If is it not available to be completed in one single test, process two or more tests.


4. The positive and negative terminals of the test object being connected to each other to create a short circuit. The resistance of the connection (including wiring) used to create short circuit should not exceeding 5mΩ.


5. Keep short circuit until any of the following conditions are met and the test is completed.

  • The protective function of the test object works and the short circuit current is terminated.
  • After the temperature of the test object's shell is stable (the temperature gradient is less than 4ºCwithin 2h), the short circuit will continue for at least 1h.

6. After testing, observe for 2h under room temperature.


Main Features


1) Vacuum Interruption, avoid electric arc to occur damage of contactor.


2) Oxidation resistance condition of the main contact parts, ensure long operation time for high current and resistance.


3) Data Acquisition: Temperature, voltage and current acquisition channels (Available for multi- channels.)


4) Control Mode: Touch screen control + computer remote control + Remote controller.


Battery Short Circuit Test Equipment Standard

  • UL 2580

Technical Parameters


Product Name


Battery External Short Circuit Current test Equipment

Model


BE-XL-10000ABE-XL-15000A

Max. Operating Current


10000A16000A

Max. Transient Current


12000A16000A

Temp. Range


Ambient Temperature

Inner Resistance


<1mΩ, <5mΩ, <10mΩ, <20mΩ, <50mΩ,<100mΩ (Optional)

Control Mode


Close PLC touch screen control + computer remote control + remote control

External Dimension


W700xD1050xH1830mmW700xD1050xH1830mm

Explosion-proof Cabinet Dimension


W2000xD3000xH2000mm (Option)

Voltage Measurement Range


0~1000V

Short Circuit Response Time


<=20ms

Data Interface


USB, Data card, etc…

Safety device


Video monitor system, explosion protection system, smoke exhaust system, smoke alarm device, explosion proof lighting device, etc.

Data Acquisition Module


Independent remote acquisition and quarantine, multi-voltage/temperature/current acquisition channels ensure data accuracy. Acquisition frequency 100HZ

Short Circuit Method


Pneumatic + vacuum arc extinguishing

Safety Alarm device


Electric leakage, over-current protection, abnormal sound-light alarm, smoke alarm, dual protection system, etc.

Testing Fixture


Customize according to actual testing condition