Two-Wire 4-20mA Two-Electrode Ozone Sensor For Drinking Water, Direct Drinking Water, Service Process Water

Brand Name:Daruifuno
Certification:CE, ISO
Model Number:OZ1.2
Minimum Order Quantity:Negotiable
Delivery Time:1-45 work days
Payment Terms:T/T
Contact Now

Add to Cart

Verified Supplier
Location: Suzhou Jiangsu China
Address: Room 301, Building 3, No. 25 Datong Road, High-tech Zone, Suzhou City, JIANGSU P.R CHINA
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details

Two-Wire 4-20mA Two-Electrode Ozone Sensor For Drinking Water, Direct Drinking Water, Service Process Water


Two-electrode system ozone sensor OZ1.2, used in drinking water, direct drinking water, service and process water, measuring water without surfactant, optional range 0~0.5/2/5/10/20ppm


The functional characteristics of the ampere film ozone sensor include high sensitivity and fast response, which can accurately measure the ozone concentration in water. Its advantages are strong anti-interference ability, suitable for various water quality environments, and long service life. It is suitable for drinking water and industrial water treatment to ensure water quality safety.


Specifications


OZ1.2

IndicatorOzone
Application

Swimming pool water, drinking water, service water, process water
The water must not contain any surfactants (tensides)!

Measuring systemMembrane covered, amperometric 2-electrode system

Electronic

Analog version: - voltage output

- not galvanically isolated electronics

- analog internal data processing

- output signal: analog (analog-out/analog)

Digital version: - electronic is completely galvanically isolated

- digital internal data processing

- output signal: analog (analog-out/digital)

or

digital (digital-out/digital)

mA-version: - current output analog

- not galvanically isolated electronics

- output signal: analog (analog-out/analog)


Information about the

measuring range

The actual slope of a sensor can vary production-related between 65% and 150% of the nominal slope

Note: With a slope > 100% the measuring range is reduced accordingly.

(Ex.: 150% slope → 67% of the specified measuring range)

Slope drift

At repeatability conditions

(25 °C, pH 7,2 in drinking water)

Approx. <- 1% per month

Working temperature

Measuring water temperature: 0 … +45 °C

(no ice crystals in measuring water)

Ambient temperature: 0 … +55 °C

Temperature

compensation

Automatically, by an integrated temperature sensor
Sudden temperature changes must be avoided


Max. allowed working pressure

Operation without retaining ring:

- 0.5 bar

- no pressure impulses and/or vibrations

Operation with retaining ring in Flow cell:

- 1.0 bar,

- no pressure impulses and/or vibrations (see option 1)



OZ1.2

Flow rate

(Incoming flow velocity)

Approx. 15-30 l/h (33 – 66 cm/s) in flow FLC, small flow rate dependence is given
pH-rangepH 1 – pH 11
Run-in timeFirst start-up approx. 1 h
Response timeT90 : approx. 15 sec.
Zero point adjustmentNot necessary
CalibrationAt the device, by analytical determination
Interferences

Cl2: factor 0.03
ClO2: factor 0.7

Absence of the disinfectantMax. 24 h

Connection

mV version:

Modbus version:

4-20 mA version:

5-pole M12, plug-on flange

5-pole M12, plug-on flange

2-pole terminal

or

5-pole M12, plug-on flange

max. length of sensor cable (depending on internal signal processing)analog< 30 m
digital

> 30 m are permissible

Maximum cable length depends on application

Protection type

5-pole M12 plug-on flange: IP68

2-pole terminal with mA-hood: IP65

MaterialSemipermeable membrane, PVC-U, ABS

Size

Diameter:

Length: mV version

Modbus version 4-20 mA version

approx. 25 mm

approx. 190 mm (analog signal processing)

approx.. 205 mm (digital signal processing)

approx. 205 mm

approx. 220 mm (2-pole-terminal)

approx. 190 mm (5-pole-M12)

Transport+5 … +50 °C (sensor, electrolyte, membrane cap)


OZ1.2


Storage

Sensor: dry and without electrolyte no limit at +5 … +40 °C

Electrolyte: in original bottle protected from sunlight at +5 … +35 °C min. 1

year or until specified EXP-Date

Membrane cap: in original packing no limit at +5 … +40 °C

(used membrane caps can not be stored)


Maintenance

Regularly control of the measuring signal, min. once a week

The following specifications depend on the water quality:

Change of the membrane cap: once a year (depending on the water quality)

Change of the electrolyte: every 3 - 6 months


Option 1:

Retaining ring


- When operating with pressures >0.5 bar in flow cell

- Dimensions retaining ring 29 x 23.4 x 2.5 mm, slitted, PETP

- Different positions for groove selectable(on request)



Technical Data

1. OZ1.2 (analog output, analog internal signal processing)
A potential-free electrical connection is necessary as the sensor electronic is not equipped with a galvanical
isolation.

Measuring range

in ppm

Resolution

in ppm

Output

Output

resistance

Nominal

slope

in mV/ppm

Voltage

supply

Connection
OZ1.2H-M120.005…2.0000.001

0…-2000 mV

1 kΩ

- 1000

±5 - ±15 VDC

10 mA

5-pole M12 plug-on flange


Function of wires:

PIN1: measuring signal

PIN2: +U

PIN3: -U

PIN4: signal GND

PIN5: n. c.

OZ1.2N-M120.05…20.000.01- 100
OZ1.2HUp-M120.005…2.0000.001

0…+2000 mV

1 kΩ

+1000

10 - 30 VDC

10 mA

5-pole M12 plug-on flange

Function of wires:


PIN1: measuring signal

PIN2: +U

PIN3: power GND

PIN4: signal GND

PIN5: n. c.

OZ1.2NUp-M120.05…20.000.01+100

(Subject to technical changes!)


2. OZ1.2 (analog output, digital signal processing)
Analog-out / digital
-The power supply is galvanically isolated inside of the sensor.
-The output signal is galvanically isolated too, that means potential-free.

Measuring

range

in ppm

Resolution

in ppm

Output

Output resistance

Nominal

Slope

in mV/ppm

Power supplyConnection
OZ1.2H-An-M120.005…2.0000.001

analog

0…-2 V

(max. -2.5 V)

1 kΩ

- 1000

9-30 VDC

approx. 20-56 mA

5-pole M12 plug-on

flange


Function of wires:

PIN1: measuring signal

PIN2: +U

PIN3: power GND

PIN4: signal GND

PIN5: n. c.

OZ1.2N-An-M120.05…20.000.01- 100
OZ1.2H-Ap-M120.005…2.0000.001

analog

0…+2 V

(max. +2.5 V)

1 kΩ

+1000
OZ1.2N-Ap-M120.05…20.000.01+100

(Subject to technical changes!)


3. OZ1.2 (digital output, digital signal processing)
-The power supply is galvanically isolated inside of the sensor.
-The output signal is galvanically isolated too, that means potential-free.

Measuring

range

in ppm

Resolution

in ppm

Output

Output resistance

Power supplyConnection
OZ1.2H-M0c0.005…2.0000.001

Modbus RTU


There are no terminating resistors in the sensor.

9-30 VDC


approx. 20-56 mA

5-pole M12 plug-on flange

Function of wires:

PIN1: reserved

PIN2: +U

PIN3: power GND

PIN4: RS485B

PIN5: RS485A

OZ1.2N-M0c0.05…20.000.01

(Subject to technical changes!)


4. OZ1.2 4-20 mA (analog output, analog internal signal processing)
A potential-free electrical connection is necessary as the sensor electronic is not equipped with a galvanical
isolation.
4.1 Electrical connection: 2 pole terminal clamp

Measuring

range

in ppm

Resolutio n

in ppm

Output

Output

resistance

Nominal

slope

in mA/ppm

Voltage

supply

Connection
OZ1.2MA0.50.005…0.5000.001

4…20 mA

uncalibrated

32.0

12…30 VDC

RL 50Ω…RL 900Ω


2-pole terminal

(2 x 1 mm²)


Recommended:

Round cable

4 mm

2 x 0.34 mm²

OZ1.2MA20.005…2.0000.0018.0
OZ1.2MA50.05…5.000.013.2
OZ1.2MA100.05…10.000.011.6
OZ1.2MA200.05…20.000.010.8

(Subject to technical changes!)

4.2 Electrical connection: 5 pole M12 plug-on flange

Measuring

range

in ppm

Resolution

in ppm

Output

Output

resistance

Nominal

slope

in mA/ppm

Voltage

supply

Connection
OZ1.2MA0.5-M120.005…0.5000.001

4…20 mA

uncalibrated

32.0

12…30 VDC

RL 50Ω…RL 900Ω

5-pole M12

plug- on flange


Function of wires:

PIN1: n. c.

PIN2: +U

PIN3: -U

PIN4: n c.

PIN5: n. c.

OZ1.2MA2-M120.005…2.0000.0018.0
OZ1.2MA5-M120.05…5.000.013.2
OZ1.2MA10-M120.05…10.000.011.6
OZ1.2MA20-M120.05…20.000.010.8

(Subject to technical changes!)


Spare Parts

TypeMembrane capElectrolyteEmeryO-ring
For all OZ1.2

M20.2
Art. no. 11011.1

EOZ1/W, 100 ml
Art. no. 11101

S1
Art. no. 11908

14 x 1.8 silicone
Art. no. 11805

(Subject to technical changes!)

China Two-Wire 4-20mA Two-Electrode Ozone Sensor For Drinking Water, Direct Drinking Water, Service Process Water supplier

Two-Wire 4-20mA Two-Electrode Ozone Sensor For Drinking Water, Direct Drinking Water, Service Process Water

Inquiry Cart 0