Product Details

0~14pH 4~20mA or 0~20mA Online pH ORP Meter Controller For Water Treatment


‍pH/ORP controller (also known as pH meter) equipment is suitable for the control of PH and ORP values in electroplating, metallurgy, textile, chemical and other wastewater, giving new life to the traditional chemical treatment method, fully realizing automatic monitoring, automatic medication, to ensure that the discharge of wastewater to meet the national discharge standards.


Advantages of pH/ORP controller:

  • pH glass electrode measurement method
  • Two configurable SPST multifunction relays
  • With 1 high-precision 0/4-20mA current output
  • 3.2 inch LCD screen, rich content
  • Support multiple installation methods
  • AC and DC power modes, both wide voltage
  • Housing material reinforced ABS, protection class IP66


pH ORP controller Parameters:

Display RangepH: 0~14pH
ORP: -2000mV~2000mV
Temp.:-10~+150℃
ResolutionpH: 0.01pH ORP: 1mV Temp.: 0.1℃
Accuracy±0.02pH/±2mV
Temp. CompensationNTC10K/PT1000 automatic or manual
Relay ControlChannel Quantity: 2
Control Type: main value control/temp. control/wash control
Contact Type: SPST
Contact Capacity: 3A 250V AC
Current OutputChannel Quantity: 1
Output Type: active 4~20mA or 0~20mA
Max. Load: 1000Ω
Display Screen3.2 inch graphic LCD display
Configuration informationPower failure protection, parameters are retained indefinitely
Operating Environment0~+60℃, relative humidity 0~95%, no condensation
Storage Environment-20~+70℃, relative humidity 0~55%, no condensation
Power Supply100~240VAC or 18~36VDC, 3W Max
Installation MethodPanel / wall / pipe mounting
Instrument Dimension144*144*120 (unit: mm)
Protection GradeIP66
Instrument WeightAbout 800g


Probe Setting
Perform sensor calibration and view of sensor status.
After the probe is connected to the controller, it needs to be calibrated first due to the error between
the signal of the actual electrode and the standard.
pH Calibration
1. Preparation before calibration
  • In the menu “ select probe ”, select “ pH Glass probe ” or “ pH Antimony probe ”
  • pH 4.01, 6.86, 9.18 standard solution (1)
  • Deionized cleaning solution and absorbent paper
2. Zero Calibration
(1) Clean the probe with deionized cleaning solution, dry it with absorbent paper and put it
into pH 6.86 standard solution;
(2) After the measured value is stable, select “ 6.86pH CAL ” to start calibration;
3. Acid slope Calibration
(1) Clean the probe with deionized cleaning solution, dry it with absorbent paper and put it
into pH 4.01 standard solution;
(2) After the measured value is stable, select “ 4.01pH CAL ” to start calibration;
4. Alkali slope Calibration
(1) Clean the probe with deionized cleaning solution, dry it with absorbent paper and put it
into pH 9.18 standard solution;
(2) After the measured value is stable, select “ 9.18pH CAL ” to start calibration;
ORP Calibration
1. Preparation before calibration
  • In the menu “ select probe ”, select “ ORP probe ”
  • ORP 86mV, 256mV standard solution (1)
  • Deionized cleaning solution and absorbent paper
2. Zero Calibration
(1) Clean the probe with deionized cleaning solution, dry it with absorbent paper and put it
into ORP 86mV standard solution ;
(2) After the measured value is stable, select " 86mV CAL " to start calibration;
3. Slope Calibration
(1) Clean the probe with deionized cleaning solution, dry it with absorbent paper and put it
into ORP 256mV standard solution;
(2) After the measured value is stable, select " 256mV CAL " to start calibration;


pH ORP controller Applications:

Water treatment monitoring: drinking water, surface water source water quality, groundwater, environmental sewage discharge monitoring, urban drainage network monitoring
Industrial process monitoring: chemical industry, petroleum, paper making, food and medicine, PCB electroplating, etc