Home /Measuring & Analysing Instrument Processing Services /

Online OTA RS485 Interface Dissolved Oxygen Analyzer For Industry Water Monitoring

Online OTA RS485 Interface Dissolved Oxygen Analyzer For Industry Water Monitoring

Brand Name:Daruifuno
Certification:CE, ISO
Model Number:DUC2-DO-S-D
Minimum Order Quantity:1
Delivery Time:5-25 days
Payment Terms:T/T, Western Union, MoneyGram
Contact Now

Add to Cart

Verified Supplier
Location: Suzhou China
Address: Suzhou Xupai Road No.3
Supplier`s last login times: within 1 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details


Online OTA RS485 Interface Dissolved Oxygen Meter For Industry Water Monitoring


Common applications for dissolved oxygen meter:

1. Aquaculture:

Guarantee the breathing needs of aquatic organisms, real-time monitoring of oxygen content, automatic alarm, automatic oxygenation and other functions.


2. Water quality monitoring in natural waters

Detect the pollution degree and self-purification ability of water bodies, and prevent biological pollution such as eutrophication of water bodies.

Therefore, the most prominent feature of the HART protocol is that digital communication is compatible with analog signals of 4 to 20 mA, and the transmitted signal is superimposed on the analog signal of 4 to 20 mA with a modulated sinusoidal signal.


3. Sewage treatment, control indicators
Anaerobic tank, aerobic tank, aeration tank and other indicators are used to control the effect of water treatment.


4. Control the corrosion of metal materials in industrial water supply pipes
Generally, a sensor with a ppb (ug/L) level range is used to control the inside of the pipeline to achieve zero oxygen to prevent rust. It is often used in power plants and boiler equipment.


Specification:

ModelDUC2-DO-S-D
Software VersionDRFN DO Analysis software V1.0
Sensor InputCompatible with all DRFN's DO Digital Sensors
Display RangeDO ConcentrationDO concentration 0-50mg/L (or ppm), unit can be switched
Saturation0-400%
TEMP-10~500℃ /14~932℉
Atmospheric Pressure30-120kpa
ResolutionDO Concentration0.01 mg/L(or ppm)
Saturation1%
TEMP0.1℃/ 0.1℉
Salinity Compensation RangeInput range 0.0001-99999ppt
Relay Control2 settable SPST relays with a maximum load of 3A/250VAC
Analog Current Output2 settable 0/4~20mA current outputs, max load 1000Ω
Communication Method

RS485 interface
MODBUS RTU
support JSON text data format

OTADefault WIFI
Display Screen128*64 LCD, adjustable backlight mode, adjustable display rate
Configuration InformationPower off protection, parameters are retained indefinitely
Time/Data Record

Record 14000 historical data
Record interval can be set between 1~999 minutes

Maintenance RecordsLast 100
Operating Temperature0~60℃,RH<95% ( no condensation)
Storage Temperature-20~70℃, RH<55% ( no condensation, precision instruments)
Shell MaterialEnhanced ABS
Protection GradeIP66
Dimension144*144*120 mm
Mounting MethodWall mounting, pipe clamping, panel (hole size 138*138 mm)
Electrical InterfaceThe back end reserved 3 M12*1.5 Gram head, line diameter 3~6.5 mm
Power Supply18~36VDC
Power ConsumptionAbout 7W
WeightAbout 800g


Please click the user manual of DO controller here:

DUC2-DO dissolved oxygen controller user manual.p...


Brief introduction:

● Compatible with DRFN digital dissolved oxygen sensors including fluorescence and polarography;
● Automatic compensation for air pressure display;
● The working status of the sensor can be queried, including reading the serial number;
● OTA download technology as a smart configuration option for the instrument;
● Time and historical data recording function;
● User-friendly Chinese and English language interface;
● Password can be set to prevent misoperation;
● 2 SPST multi-function and settable relays;
● Two 0/4~20mA active current loop outputs;
● RS485 interface, Modbus RTU communication protocol;
● IP66 waterproof level, sealed enclosure can isolate pollution and corrosive gas;
● Support a variety of installation methods


Aplication:
◇ Sewage
◇ Surface water monitoring
◇ Aquaculture water bodies
◇ Urban sewage treatment
◇ Industrial wastewater treatment
◇ Aquarium


FAQ
1. Which sensors can be connected to your dissolved oxygen controller?

A: The dissolved oxygen meter can be compatible with DRFN digital dissolved oxygen sensors including fluorescence and polarography.


2. How does your DO controller collect sensor data?
A: The connected sensor uploads the detected data in a special encrypted communication method to ensure that the DUC controller can collect high-precision data more stably


3. What are the applications of dissolved oxygen analyzers?
A: Sewage/Surface water monitoring/Aquaculture water bodies/Urban sewage treatment/Industrial wastewater treatment /Aquariums


4.Can the dissolved oxygen controller realize the automatic cleaning control functi​on?
The DO controller has a self-cleaning control function, and Our DO sensor has a cleaning interface.
The end customer can choose water or air, Realize automatic cleaning. But the end user need to buy a solenoid valve himself.


5. Does the dissolved oxygen controller have an ambient temperature alarm function?
Our DO controller has ambient temperature alarm function


6: What is your shipping method?
A: Small orders are delivered with DHL, FedEx, TNT, UPS , EMS. Large orders are recommended to ship by sea.


7: Do you provide samples ?
A: Yes,we have materials in stock to help you to get the samples as soon as we can.

China Online OTA RS485 Interface Dissolved Oxygen Analyzer For Industry Water Monitoring supplier

Online OTA RS485 Interface Dissolved Oxygen Analyzer For Industry Water Monitoring

Inquiry Cart 0