

Add to Cart
Digital Online Chlorine Dioxide Controller RS485 For Swimming Pools Disinfectant
Product Introduction
Chlorine dioxide disinfectant is an internationally recognized high-efficiency disinfectant. It is very safe and has no residual toxicity. With the widespread application of chlorine dioxide as a disinfectant, it is very important to detect and control its concentration. DRFN’s DUC2-CD-H chlorine dioxide controller is used for the measurement of chlorine dioxide. It is a digital meter, which can be connected to DRFN’s digital chlorine dioxide sensors.
Features Of The Chlorine Dioxide Controller
● RS485 interface, MODBUS RTU communication protocol
● Time and historical data recording function
● 128*64 large LCD screen, adjustable backlight mode
● Power-off protection configuration, parameters can be kept indefinitely
● A variety of installation methods: wall, pipe clamping, and panel installation
● 2 settable 0/4~20mA active current loop outputs
● Provide AC or DC power supply mode, both of which are wide-voltage power supply
Applications Of The Chlorine Dioxide Controller
● Disinfection Systems
● Cooling Towers
● Water Treatment
Technical Parameters
Product Name | Chlorine Dioxide Controller |
Product Model | DUC2-CD-H |
Software Version | DRFN chlorine dioxide Analysis software V1.0 |
Display Range | 0.01mg/L~100g/L |
Resolution | 0.01mg/L |
Relay Control | 2 settable SPST relays max. load 3A/250VAC |
Analog Current Output | 2 settable 0/4~20mA active current loop output max. load 1000Ω |
Communication Method | Two-wire RS485 interface; MODBUS RTU; support JSON text data format |
Display Screen | 128*64 LCD, adjustable backlight mode, adjustable display rate |
Time/Data Record | Year/month/day/hour/min/second, record 14000 historical data, record interval can be set between 1~999 minutes |
Maintenance Records | Last 100 times |
Protection Level | IP66 |
Operating Environment | 0~60℃, relative humidity less than 95% (no condensation) |
Storage Environment | -20~70℃, relative humidity less than 55% (no condensation) |
Shell Material | Enhanced ABS |
Size | 144*144*120mm (hole size 138*138 mm) |
Mounting Method | Wall mounting, pipe clamping, panel mounting |
Power Supply | 18~36V DC or 100~240V AC |
Weight | 800g |
Power Consumption | 7W |
The Suitable Chlorine Dioxide Sensors Recommendation
Pressure range: 0~8 bar
Shaft length: standard 175 mm
Type: (50℃) | Measuring range: ppm | Resolution: ppm | Output signal | Power supply | Item number |
AS2H-CD-M0c | 0.005~2.00 | 0.001 | Modbus RTU | 9~30 V DC 20~56 mA | 3426820 |
AS2N-CD-M0c | 0.03~10.00 | 0.01 | 3426821 |
Type: (70℃) | Measuring range: ppm | Resolution: ppm | Output signal | Power supply | Item number |
AS3H-CD-M0c | 0.005~2.00 | 0.001 | Modbus RTU | 9~30 V DC 20~56 mA | 3426870 |
AS3N-CD-M0c | 0.03~10.00 | 0.01 | 3426871 |
Pressure range: 0~1 bar
Shaft length: standard 175 mm
Type | Measuring range: ppm | Resolution: ppm | Output signal | Power supply | Item number |
CD4.2H-M0c | 0.005~2.000 | 0.001 | Modbus RTU | 9~30 V DC 20~56 mA | 3326465 |
CD4.2N-M0c | 0.05~20.00 | 0.01 | 3326466 |
Pressure range: 0~1 bar
Shaft length: standard 175 mm
Type | Measuring range: ppm | Resolution: ppm | Output signal | Power supply | Item number |
CD7H-M0c | 0.005~2.000 | 0.001 | Modbus RTU | 9~30 VD 20~56 mA | 3226620 |
CD7N-M0c | 0.05~20.00 | 0.01 | 3226621 | ||
CD7L-M0c | 0.5~ 200.0 | 0.1 | 3226622 |
Pressure range: 0~1 bar
Shaft length: standard 175 mm
Type | Measuring range: ppm | Resolution: ppm | Output signal | Power supply | Item number |
CD10H-M0c | 0.005~2.000 | 0.001 | Modbus RTU | 9~30 VD 20~56 mA | 3426220 |
CD10N-M0c | 0.05~20.00 | 0.01 | 3426221 |