UV254nm RS485 Chemical Oxygen Demand Analyzer Probe Modbus RTU

Brand Name:Daruifuno
Certification:CE
Model Number:CODuv351
Minimum Order Quantity:Negotiable
Place of Origin:China
Price:Negotiable
Contact Now

Add to Cart

Verified Supplier
Location: Suzhou Jiangsu China
Address: Room 301, Building 3, No. 25 Datong Road, High-tech Zone, Suzhou City, JIANGSU P.R CHINA
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details

Chemical Oxygen Demand Probe UV254nm COD Sensor With RS485 Modbus RTU


The COD probe of Daruifuno adopts Spectral Absorption Coefficient (SAC) method, which can measure the absorption of light at a specific wavelength. The sensor doesn't need consumables during the measurement process. The COD electrode can measure COD, TOC, turbidity, temperature and other parameters. It uses two light sources, 254nm and 365nm UV reference light.


Measuring Principle Of The COD Probe


Many organic substances dissolved in water absorb ultraviolet rays, and the electromagnetic spectrum ranges from 200 to 390 nm. The simplest form of measurement using this principle is the Spectral Absorption Coefficient (SAC), which can measure the absorption of light at a specific wavelength. Traditionally, a wavelength of 254nm is used because it is located in an area sensitive to organic absorption.


Therefore, by measuring the degree of absorption of ultraviolet light with a wavelength of 254 nm by organic substances, the substitution of organic substances in water can be detected.


The chemical oxygen demand(COD) sensor can be used in a wide range of applications.


Advantages Of The COD Probe

  • Automatically eliminate the interference of suspended solids and compensate for the interference of turbidity

  • Excellent test performance, achieve more stable and reliable measurement values

  • Integrated self-cleaning brush, small size and convenient to install, continuously monitor water quality online to prevent biological attachment and effectively reduce the frequency of maintenance.

  • Digital sensor, RS485 output, support MODBUS communication.

  • Drop-in installation, the tested sample does not need to be digested, the analysis speed is fast, no reagents need to be added, and there is no special sampling equipment.

  • The measurement process responds quickly in real-time without waiting.


Applications Of The COD Probe


  • Monitoring for compliance
  • Optimization of wastewater treatment processes
  • Development of process control algorithms
  • Identification of cross-connected sewers
  • Identification of pollution sources
  • Rapid assessment of incident severity
  • Advanced treatment monitoring & protection
  • Effluent pollution

Technical Parameters


Product NameCOD probe
Product ModelCODuv351
Measuring PrincipleUV254 ultraviolet absorption method
Measuring Range(COD)0.75~370mg/L
Resolution(COD)0.01mg/L
Accuracy(COD)±2% or ±2.5mg/L, take the larger one
Measuring Range(TOC)0.3 ~150mg/L
Accuracy(TOC)±2% or ±2.5mg/L, take the larger one
Resolution(TOC)0.1mg/L
Measuring Range(TU)0-300 NTU
Accuracy(TU)3% or 0.2NTU, take the larger one
Resolution(TU)0.1NTU
Operating Temperature+5 ~ 45℃
Calibration2-point calibration
Protection GradeIP68
Working Pressure1Bar
Response TimeT90 max. 10s
Flow Rate< 3 m/s
Cleaning MethodRubber scraper
Power12V 15mA (normal), 200mA (maximum, when cleaning)
OutputRS485, Modbus RTU protocol
DimensionDiameter 50mm, length 215mm
Cable Length10m(custom)
Shell MaterialPOM and 316L

The Matched COD Controller Parameter


Product NameCOD analyzer
Product ModelDUC2-COD-H
Software VersionDRFN COD analysis software V1.0
Display Range0-1000 mg/L
Resolution0.01 mg/L
Relay Control2 settable SPST relays max. load 3A/250VAC
Analog Current Output2 settable 0/4~20mA active current loop output max. load 1000Ω
Communication MethodTwo-wire RS485 interface; MODBUS RTU; support JSON text data format
Display Screen128*64 LCD
Time History/Data RecordYear/month/day/hour/min/second, record 14000 historical data
Protection LevelIP66
Operating Environment0~60℃, relative humidity less than 95% (no condensation)
Storage Environment-20~70℃, relative humidity less than 55% (no condensation)
Shell MaterialEnhanced ABS
Size144*144*120mm (hole size 138*138 mm)
Mounting MethodWall mounting, pipe clamping, panel mounting
Power Supply18 ~ 36V DC or 100~240V AC
Weight800g
Power Consumption12W

China UV254nm RS485 Chemical Oxygen Demand Analyzer Probe Modbus RTU supplier

UV254nm RS485 Chemical Oxygen Demand Analyzer Probe Modbus RTU

Inquiry Cart 0