Home Use Class III IP20 1500V 3P 40KA Surge Protection Device

Brand Name:Uchi
Certification:CE / SGS / ISO9001
Model Number:OBV-II40kA
Minimum Order Quantity:200 piece
Delivery Time:5-15 days after payment
Payment Terms:T/T, L/C, Western Union
Contact Now

Add to Cart

Active Member
Location: Dongguan China
Address: Floor 4, NO.25-29,Power Station Road, Xihu , Shilong Town , Dongguan 523325, China.
Supplier`s last login times: within 14 hours
Product Details Company Profile
Product Details

Class III IP20 1500V 3P 40kA Surge Protection Device for house use


Uc(maximum continuous operating voltage)1500Ucpv
Imax(maximum discharge current)40kA
In(nominal discharge current for class II test)20kA
Up(voltage protection level)≤2.0kv
Combination3P
response time≤25ns
Signal deterioration indicationRed: replace
Green:ok
Housing Materialthermoplastic material
Housing self-extinguishing classUL94_V0
Temperature range-40℃~+80℃
humidity range5%RH~95%RH
Elevational≤3000m
Method of connecting wireParallel Connect
Thread Dimensions4~35mm2
Mounting methodDIN:35mm
IP(degree of protection of enclosure)IP20
Follow up standardIEC 61643-1,GB/T 18802.1

Feature:


1. Small size, easy to plug and replace
2. Fault resistant Y-type circuit, composed of three varistors and thermal tripping device in series
3. Double tripping protection device to provide more reliable protection
4. Large flow and quick response
5. Multi-function connection port can connect wire and bus bar
6. When the fault window pops open in green, and provides remote monitoring through the warning port


Installation Instructions:


1. Power must be cut off before installation, and live operation is strictly prohibited
2. It is suggested to connect the fuse or automatic short-circuit in series at the front end of the lightning protection module
3. Please connect according to the installation diagram, where + is the positive wire, - is the negative wire, and PE is the ground wire. Don't make a mistake. After the installation is completed, close the switch and check whether the working condition is normal
4. Insert the module in place after installation and check whether the lightning protection module works normally
5. During the use of SPD, it should be regularly monitored and checked the status of the fault display window. When the fault display window is red or the remote terminal output an alarm signal, it indicates that the lightning protection module has broken down and should be repaired or replaced in time
6. Lightning protection module should be installed in parallel, and the connecting line should be firm and reliable, and it should be short, thick and straight