PBT Material PV Surge Protector 3 Phase Network Voltage 600VDC For Solar System

Brand Name:Uchi
Certification:CE / SGS / ISO9001
Model Number:OBV5-C40-PV
Minimum Order Quantity:200 piece
Delivery Time:5-15 days after payment
Payment Terms:T/T, L/C, Western Union
Contact Now

Add to Cart

Active Member
Location: Dongguan China
Address: Floor 4, NO.25-29,Power Station Road, Xihu , Shilong Town , Dongguan 523325, China.
Supplier`s last login times: within 14 hours
Product Details Company Profile
Product Details

600V PV Surge Protector , Three Phase Surge Diverter For Solar System


OBV5-C40-PV


Prewired modular complete unit for use in photovoltaic systems consisting of a base part and plug-in protection modules

Combined disconnection and short-circuiting device with safe electrical isolation in the protection module prevents fire damage resulting from d.c. switching arcs (patented SCI principle)

Tried and tested fault-resistant Y circuit of the OBV6-C40-PV prevents damage to the surge protective device in case of insulation faults in the generator circuit.

Integrated d.c. fuse allows safe replacement of protection modules without arc formation.


Technical Parameters


Model: OBV5-C40-PV
Network voltage500Vdc600Vdc800Vdc900Vdc1000 Vdc
Max. operating voltage Uc530Vdc630Vdc840Vdc950Vdc1060 Vdc
Nominal discharge current ln20kA
Max. discharge current lmax40kA
Protection level (at In) Up1.8kV2.5kV2.8kV3.0kV3.2kV
Disconnector
Thermal DisconnectorInternal
Mechanical characteristics
Connectionby screw terminals: 4-25 mm2
Disconnection indicator1 mechanical indicator by pole
Mountingsymmetrical rail 35 mm
Operating temperature-40/+85°C
Protection classIP20
Standards compliance
NF EN 61643-11 FranceParafoudre Basse Tension - Essais Classe II
IEC 61643-1 InternationalLow Voltage SPD - Test Class II
EN 61643-11 EuropeParafoudre Basse Tension - Essais Classe II

Feature&Benefits

-Easy installation or retrofit

-Din-rail mountable
-Fail-safe /self-protected designRemote indicator (optional) with 3pin NO/NC contact
-IP20 finger-safe designVisual indicator
-Small foot print

Application


●AC/DC distribution
●Power supplies
●Industrial automation
●Telecommunications
●Motor controls systems
●PLC applications
●Power transfer equipment
●HVAC applications
● AC drives
●UPS systems
●Security systems
●IT/Data centers

Others


Technology SPD parameter(Note:According to user requirement ,can be customized Uc=140V,440V,550V,voltage range of range of the SPD):

Type No.Rated Voltage(V) UnContinuous Voltage Uc(V~)Standard Discharge Current In(KA)

Max Discharge Current
Imax(KA)

Protection Level(KA~)Response Time(ns)
DGM1(2)-D5220/380

275/320
385/420

5101.2≤25
DGM1(2)-D101021.6
DGM1(2)-C2020401.8
DGM13-B303060.2.2
DGM3(4)-B4010802.4
DGM(4)-B60601002.8
DGM-N-PE220/25540/6060/801.2≤100

Tip1:How can we distinguish the quality of the lightning arrester?

1. It can be seen from the reaction time: determine whether the lightning arrester can respond in time and quickly discharge the lightning current.

2. It can be seen from the insertion loss: this refers to the installation of a lightning protector, the impact of this lightning protector on the line, the smaller the better

3. It can be seen from the number of impact resistance: determines the service life of the lightning arrester. Generally, the gas discharge tube will not drop after being placed for a period of time. If you want to check its quality, you can use an adjustable high-voltage DC power supply to test .


Tip2.What skills should lightning protectors have in the selection?
1.Confirm power supply system
First of all, you must determine what your power distribution system is like, whether it is TT, TN or IT system. After determining the power distribution system, you can choose the protection mode and wiring method of the lightning arrester to select the appropriate lightning arrester.
For example, TN-C uses 3P lightning protection device, TN-S uses 4P, TT uses 3P+N, etc.
2.Know the main parameters of the lightning arrester.

Note: The difference between T1 type and T2 type surge protector


The T1 type surge protector refers to the product with the lightning test waveform of 10/350us, and the T2 type surge protector refers to the product with the lightning test waveform of 8/20us.

The main difference between the two types of surge protectors lies in the different test waveforms. The energy of the 10/350us waveform is stronger than the energy of the 8/20us waveform, so in many cases the T1 surge protector is generally 12.5kA, 15kA, 25kA, etc. , T2 surge protector does have 20kA, 40kA, 60KA, 100kA, etc. Although the value of T2 type surge protector looks larger, their test waveforms are different. In fact, the energy of T1 is stronger.

Therefore, the national standard GB50057-2010 requires the installation of a T1 type surge protector in the main incoming line, which is also the first-level surge protector. When selecting the type, pay attention to the surge protector must have a T1 test Iimp (10/350us) test This parameter is generally Iimp is greater than or equal to 12.5kA, and the protection level Up≤2.5kV is enough.

What skills should lightning protectors have in the selection?
1.Confirm power supply system
First of all, you must determine what your power distribution system is like, whether it is TT, TN or IT system. After determining the power distribution system, you can choose the protection mode and wiring method of the lightning arrester to select the appropriate lightning arrester.
For example, TN-C uses 3P lightning protection device, TN-S uses 4P, TT uses 3P+N, etc.
2.Know the main parameters of the lightning arrester.
FAQ


Q: Can I get some samples?
A: Yes, Sample orders welcomed.

Q: Can I use my own Logo or design on goods?
A: Yes, Customized logo and design on mass production are available.

Q:What is the delivery time?
A: 3 days for samples, 7-15 days for mass production.

Q: What is the payment term?
A: T/T, L/C at sight, West union , Paypal, etc.

China PBT Material PV Surge Protector 3 Phase Network Voltage 600VDC For Solar System supplier

PBT Material PV Surge Protector 3 Phase Network Voltage 600VDC For Solar System

Inquiry Cart 0