DN15 Central Heating Zone Valve , Two Port Zone Valve With DC Actuator Motor

Brand Name:Runpaq
Certification:CE
Model Number:60P-T2-15-2
Minimum Order Quantity:50 pieces
Delivery Time:15-21 days
Payment Terms:L/C, T/T, D/A, D/P, Western Union
Contact Now

Add to Cart

Active Member
Location: Shanghai Shanghai China
Address: Room E202, No. 4528 Jiasong Road (Middle), Qingpu district 201705, Shanghai, China
Supplier`s last login times: within 7 hours
Product Details Company Profile
Product Details

central zone heating valves with 2 port motorized valve / dC actuator motor, dN15


Product Description

The zone valves on central heating and cooling systems, heating boilers, it controls hot water heat or cold water. In all cases, when the zone control valve is fully open, an "end switch" inside the valve tells the heating system's circulator to begin operating, causing hot water to flow through the zone.
Our zone control valve is a range of 2-way motorized zone valve, which is with motor actuator for use in heating and cooling system. The brass or stainless ball valve is available in DN15-32, PN10 with thread connection. The actuator is controlled by 2-point signal and is recommended for on/off function, available for 230V AC, 50/60Hz or DC power supply.

Features

  • Metal gearbox and metal gear design, low noise, perform reliably
  • Long service life: more than 100000 circles
  • Electric limit and machinery limit design, located accurately, avoid gear run continuously.
  • Mufti-angle assembling, easy to install
  • Float ball structure, no leakage, especially suitable for heavy pollution conditions.
  • Can work in boiler water room, good substitution for solenoid valve

Application

  • HVAC system heating, ventilation, air conditioning
  • Baseboard/radiant heating
  • Convectors
  • Fan coil units
  • Underfloor heating
  • Unit ventilators
  • VAV reheat

Advantages

  • Sturday valve body with reasonable structure design, and best material to be used
No.OursNormal products
Valve shaft sealQuadruple sealsDual seals
Nut sealAuto super anaerobic glue coating, Consistent torque tighteningManual anaerobic glue, unevenly, non consistent torque tightening
Seal between valve body and housingSeal groovenone
TorqueSmoothly and lightHeavy, non consistently
DrainageYesnone


Technical data

Model60P
Work Amp (mA)Max100mA(CR04 except Max150mA)
ProtectionIP65
Power (W)<5
Operate Pressure (Mpa)PN10
Torque (NM)6
Dia rangeDN8-32
Open/close (S)< 8s
Work volt. (V)DC3-6V, DC12V, AC/DC9-24V, AC220V, AC85-265V
Media temp (℃)0-90
ControlCR01, CR02, CR02+, CR03, CR03A, CR03T, CR04 CR05, CR06
Dimensions
Valve body materialConnection portDiameterDLHW
(mm)(Kg)
BrassBoth female thread full diameterDN8846310.402
DN151557380.478
DN202071450.559
DN2523.572490.648
Both female reduced diameterDN10846310.401
DN201566380.493
DN252072470.653
DN322586600.865
3 way verticalDN151263490.48
DN201566530.537
CPVCBoth male threadDN151560470.357
DN202072510.385
Brass3-way horizontalDN8652.63924.5
DN1512725539
DN20158663.544
DN25159768.543.5

Wiring options

  • Two wires and reverse polarity (DC3-6V / DC12V / DC24V)

1. Connecting SW to OPEN , the valve opens , getting the position ,automatically power off, the valve remain fully open position

2. Connection SW to CLOSE , the valve close , getting the position ,automatically power off, the valve remains side passes position(fully closed)

  • Three wires and two control points (DC3-6V / DC12V / DC24V)

1. Connecting SW to OPEN, the valve opens , getting the position ,automatically power off, the valve remain fully open position

2. Connection SW to CLOSED, the valve close , getting the position ,automatically power off, the valve remains side passes position (fully closed)

Note: AC24V/AC220V can only be used for 50K series electric valves

  • three wires&fail-safe/power-off return (DC9-24V)

1. Connecting SW to OPEN, the valve opens, getting the position and automatically power off, the valve remains

fully open position

2. Disconnecting SW to CLOSE, the valve closes, getting the position and automatically power off, the valve remains fully close position

Note: As the power-off and valve will be return automatically, and RD/G(B)/Y(B) 3 wires can’t be power-on together to keep valve safe

  • three wires one point control (DC3-6V/ADC9-24V/AC220V)

1. Connecting SW, the valve opens, getting the position, automatically power off, the valve remains fully open position

2. Disconnecting SW, the valve closes, getting the position, automatically power off, the valve remains fully close position

Note: When power is DC voltage and Red Wires is “+”, Blue wire is “—”

  • wiring diagram (angle adjustable) (DC9-24V)

1. SW1 open, SW2 open, valve full close, getting the position valve remains fully close position

2. SW1 close, SW2 open, valve open 30 degree, getting the position valve remains open 30 degree position

3. SW2 close, SW1 open, valve open 60 degree, getting the position valve remains open 60 degree position

4. SW1 close, SW2 close, valve full open, getting the position valve remains fully open position

  • wiring diagram (angle adjustable) (DC9-24V)

1. Connecting SW, the valve opens, getting the position, automatically power off, the valve remains fully open position

2. Disconnecting SW, the valve close, getting the position, automatically power off, the valve remains fully close position

  • wiring diagram(two wires and fail-safe/power-off return)(DC3-6V/ADC9-24V/AC220V)

1. SW connecting, the valve open, getting the position and the power off automatically, the valve remains fully open/close position

2. SW disconnecting, the valve close, getting the position and power off automatically, the valve remains fully open/close position

  • five wires micro controller with signal feedback (DC3-6V/ 12V / 24V)

1. Connecting SW and OPEN, the valve opens, getting the position green wire output the OLS signal, the controller tests the signal OLS, connect SW to STOP, the valve stops and remains fully open position

2. Connecting SW and CLOSE, the valve close, getting the position red wire output the CLS signal, the controller tests the signal CLS, connect SW to STOP, the valve stops and remains fully close position,

Note: Please make sure the signal wires "red", "black" and "green" be connected at first, then connect the power wires " yellow" and "blue"


Factory show


China DN15 Central Heating Zone Valve , Two Port Zone Valve With DC Actuator Motor supplier

DN15 Central Heating Zone Valve , Two Port Zone Valve With DC Actuator Motor

Inquiry Cart 0