Home /

Quick Check Combo Rapid Test Kit For Medical Healthcare

Quick Check Combo Rapid Test Kit For Medical Healthcare

Brand Name:Vchek
Minimum Order Quantity:negotiable
Delivery Time:10-15days
Payment Terms:T/T, Western Union
Place of Origin:China
Price:negotiable
Contact Now

Add to Cart

Verified Supplier
Location: Guangzhou China
Address: Guangzhou Decheng Biotechnology Co., LTD Room 218, Building 2, No.68, Nanxiang Road, Science City, Huangpu District, 510000
Supplier`s last login times: within 25 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

2019nCov Ag Combo Rapid Test Kit

Advantages:

Inexpensive

Simple to use, saliva samples, no instrument needed

Non-invasive, fast, result in 15 minutes.

Accurate and reliable compared to molecular methods


Uses:

Early supplementary screening of 2019-nCoV infection for clinics, hospitals and CDC.

Screening for return to work in public institution and companies.

Screening for suspected population.

Screening for students returning to school.

It will keep for 24 months if stored in a cool and dry place at 2~30℃, away from sunlight, moisture, heat and frozen condition. After opening the package, the kit is effective if used in 1 hour under room temperature (25℃) and humidity (<60%).


SUMMARY AND EXPLANATION

The novel coronaviruses belong to the β genus. COVID-19 is an acute respiratory infectious disease. People are generally susceptible. Currently, the patients infected by the novel coronavirus are the main source of infection; asymptomatic infected people can also be an infectious source. Based on the current epidemiological investigation, the incubation period is 1 to 14 days, mostly 3 to 7 days. The main manifestations include fever, fatigue and dry cough. Nasal congestion, runny nose, sore throat, myalgia and diarrhea are found in a few cases.


PRINCIPLE OF THE TEST

This test uses double-antibody sandwich to legally detect the antigen of novel coronavirus (2019-nCoV) in saliva samples. During detection, the gold labeled anti-2019-nCoV monoclonal antibody in the labeling pad binds to the 2019-nCoV antigen in the sample to form a complex, and the reaction complex moves forward along the nitrocellulose membrane under the action of chromatography, it is captured by the anti-2019-nCoV monoclonal antibody pre-coated by the detection zone (T) on the nitrocellulose membrane, and finally a red color reaction line is formed in the T zone. If the sample does not contain 2019-nCoV antigen, a red color reaction line cannot be formed in the T zone. Regardless of whether the sample to be tested contains 2019-nCoV antigen, a red reaction line will always form in the quality control area (C).


MATERIALS AND COMPONENTS


Materials provided with the test


IngredientsCassetteInstructions for useQuick Reference Instructions
Specifications
0674C4X00111NA
0674C4X00221NA
0674C4X005311
0674C4X0101011
0674C4X0202011
0674C4X0252511

Materials required but not provided

  • Timer

STORAGE AND STABILITY

  • Store the test as packaged between 2-30°C.
  • The Test stable until the expiration date printed on the outer packing, the product will be expired after 24 months.
  • Do not use beyond the expiration date.
  • Do not freeze any contents of the test
  • The test must remain in the sealed pouch until use.

TEST PROCEDURE

Before test, please read the instructions carefully.

  • Take the cassette to equilibrate to room temperature.
  • Unpack the aluminum foil bag, take out the cassette.
  • Insert the absorber end of the cassette into mouth. Make sure cassette is horizontal statement.

  • Actively swab the inside of the mouth and tongue to collect oral fluid.
  • Remove the absorber end from the mouth when the purple color move across the result window in the center of the test device.
  • Wait for 10 minutes and read the results.

NOTE:

*When sampling, gently hold it in mouth and let saliva naturally adsorb on the sponge.

*Do not eat, drink, or smoke prior to the test for at least 30 Minutes.

*Any saliva specimen is appropriate for testing but the saliva specimen collected in the morning, before mouth rinsed, eating or drinking, is recommended


INTERPRETATION OF TEST RESULTS

This product can only perform qualitative analysis on the detection object.

Positive Result:

If both C and T lines are visible within 10 minutes, the test result is positive and valid.

Negative Result:

If test area (T line) has no color and the control area displays a colored line, the result is negative and valid

Invalid Result:

The test result is invalid if a colored line does not form in the control region. The sample must be re-tested, using a new test.


INTERNAL CONTROL

The test contains a built-in internal control in the test card. A color band appearing in the control region (C) is designed as an internal control. The appearance of the control line confirms that sufficient flow has occurred, and that the test card is working normally. If the control line does not appear within 10 minutes, it is considered an error in the test result and it is recommended to test again with the same sample and a new device.


LIMITATIONS

  • The result of the test should not be taken as a confirmed diagnosis, for clinical reference only. Judgement should be made along with RT-PCR results, clinical symptoms, epidemiological information, and further clinical data.
  • The Test performance depends on the amount of virus (antigen) in the sample and may or may not correlate with viral culture results performed on the same sample.
  • The test must be equilibrated to room temperature (18℃~26℃) before used, otherwise the results may be incorrect
  • A negative test result may occur if the level of antigen in a sample is below the detection limit of the test.
  • Failure to follow the Test Procedure may adversely affect test performance and/or invalidate the test result.
  • React less than 10 minutes may lead a false negative result; React more than 10 minutes may lead a false positive result.
  • Positive test results do not rule out co-infections with other pathogens.
  • Negative test results are not intended to rule in other viral or bacterial infections.
  • Negative results should be treated as presumptive and confirmed with a molecular assay.
  • Clinical performance was evaluated with fresh samples.
  • Users should test specimens as quickly as possible after specimen collection.

PERFORMANCE CHARACTERISTIC

1. Clinical Verification

The performance of Test was established with 232 sample collected from symptomatic patients, who with symptoms onset within 7 days.


2019-nCoV Saliva Ag EASY TESTComparative RT-PCR Test Result
(Immunochromatography)
Positive (+)Negative (-)Total
Detected Positive1081109
Detected Negative7116123
Total115117232
Sensitivity93.91%, 95% CI (87.97,97.02)
Specificity99.15%, 95% CI (95.32, 99.85)
Accuracy96.55%, 95% CI (93.34, 98.24)

Positive results broken down by CT value:


2019-nCoV Saliva Ag EASY TESTComparative RT-PCR Method
(Immunochromatography)(Positive by Ct Value)
Positive (Ct<=25)Positive (25<Ct)
Detected Positive6939
Total7045
Positive agreement98.57%86.67%

2. Limit of Detection

The experimental results show that for the virus culture concentration above 100 TCID50/mL, the positive rate of detection is greater than or equal to 95%. For the virus culture concentration of 50 TCID50/mL and below, the positive rate of detection is lower than 95%. So, the limit of detection of the Test Card is 100 TCID50/mL.

3. Cross-reactivity

Cross-reactivity of the test card was evaluated. The results showed no cross reactivity with the following specimen.


4. Interference Substances

The test results do not be interfered with the substance at the following concentration:


5. Precision

1. Test 10 replicates of negative and positive by using the reference materials of enterprises. The negative agreement and the positive agreement were 100%.

2. Test three different lots kits including positive and negative reference materials of enterprises. The negative results and the positive results were 100%

6. Hook Effect

The Test Card was tested up to 1.6 × 105 TCID50/ml of heat-inactivated 2019-nCoV strain and no high-dose effect was observed.


PRECAUTIONS

  • For in vitro diagnostic use.
  • Use appropriate precautions in the collection, handling, storage, and disposal of patient samples and used test contents.
  • Use of Nitrile, Latex (or equivalent) gloves is recommended when handling patient samples.
  • Do not reuse the used Test Card or saliva swab.
  • Should never open the foil pouch of the Test Card exposing it to the ambient environment until the Test Card is ready for immediate use.
  • Discard and do not use any damaged or dropped Test Card or material.
  • Inadequate or inappropriate sample collection, storage, and transport may yield false test results.
  • Sample collection and handling procedures require specific training and guidance.
  • To obtain accurate results, do not use visually bloody or overly viscous samples.
  • To obtain accurate results, an opened and exposed Test Card should not be used.
  • Testing should be performed in an area with adequate ventilation.
  • Wear suitable protective clothing, gloves, and eye/face protection when handling the contents of this test.
  • Wash hands thoroughly after handling.

KEY TO SYMBOLS USED

Materials IncludedTest Cassette
Instructions for UseDate of
Manufacturer
Consult InstructionsDo Not Reuse
For Use
Store at 2°C~30°CCatalogue Number
Expiration DateKeep away from Sunlight
ManufacturerTests per Kit
Lot NumberIn Vitro Diagnostic Medical Device
Keep Dry
Guangzhou Decheng Biotechnology Co., LTD
Room 218, Building 2, No.68, Nanxiang Road, Science City, Huangpu District, 510000, Guangzhou P.R.China
TEL:+86-020-82557192
sales@dochekbio.com
www.dochekbio.com
CMC Medical Devices & Drugs S.L.
C/ Horacio Lengo Nº 18, CP 29006,
Málaga, Spain

China Quick Check Combo Rapid Test Kit For Medical Healthcare supplier

Quick Check Combo Rapid Test Kit For Medical Healthcare

Inquiry Cart 0