Reinforced Endotracheal Tube With Suction Lumen Soft Tip

Brand Name:MCREAT/OEM
Certification:CE, ISO,FDA,FSC
Model Number:#3.0-#10.0
Minimum Order Quantity:5000pieces
Delivery Time:3-45 Days
Payment Terms:T/T, D/A, D/P
Contact Now

Add to Cart

Verified Supplier
Location: Guangzhou Guangdong China
Address: 3rd-Floor, B15 Huachuang Industry Area, Jinshan Cun, Shiji Town, Panyu District, Guangzhou, Guangdong China
Supplier`s last login times: within 26 hours
Product Details Company Profile
Product Details

Reinforced Endotracheal Tube With Suction Lumen Soft Tip


After the glottis was exposed under direct vision with the aid of laryngoscope, the catheter was inserted into the trachea through the mouth.


Tilt client's head back and lift jaw forward and upward with both hands to open mouth, or rotate mouth with right thumb pointing at lower teeth and pointing at upper teeth.


Hold the handle of the laryngoscope in the left hand, put the laryngoscope into the mouth through the right corner, push the tongue to the side, and then slowly advance to the uvula. Lift the lens vertically forward until the epiglottis is exposed. Raise the epiglottis to expose the glottis.


If intubation with curved lens is used, place the lens at the junction of epiglottis and tongue root (epiglottis valley), lift the lens forward and upward forcefully, so that the hyoid epiglottis ligament is tense, and the epiglottis is tilted close to the laryngoscope, that is, the glottis is exposed. If intubated with straight lenses, the epiglottis should be raised directly to expose the glottis.


Hold the middle and upper segments of the catheter with your right thumb, index finger and middle finger as if holding a pen, enter the mouth through the right corner of the mouth, and move the end of the catheter to the laryngoscope until the catheter approaches the laryngoscope. At the same time, monitor the direction of the catheter through the narrow gap between the lens and the tube wall, and accurately and lightly insert the tip of the catheter into the glottis. With the help of tube core intubation, when the tip of the tube enters the acoustic door, the tube core should be pulled out before the tube is inserted into the trachea.


The depth of the catheter into the trachea for adults is 4-5cm, and the distance from the catheter tip to the incisor teeth is about 18-22cm.


After intubation is complete, ensure that the catheter is inserted into the trachea before fixation.


Reinforced Endotracheal Tube With Suction Lumen Soft Tip


Product Description


Cat.NOID(mm)OD(mm)Length(mm)
MC-154303.05.8185
MC-154353.56.3195
MC-154404.06.8215
MC-154454.57.4240
MC-154505.08.3256
MC-154555.58.9286
MC-154606.09.5295
MC-154656.510.0301
MC-154707.010.7315
MC-154757.511.5325
MC-154808.012.0337
MC-154858.512.7337
MC-154909.013.0337
MC-154959.513.6337
MC-1541010.014.7337




















China Reinforced Endotracheal Tube With Suction Lumen Soft Tip supplier

Reinforced Endotracheal Tube With Suction Lumen Soft Tip

Inquiry Cart 0