Economical Flowmeter 4-20mA RS485 DN15~DN80 Pipeline Gas Flowmeter CS VA520

Brand Name:YunYi
Model Number:VA520
Minimum Order Quantity:1 piece
Delivery Time:7days
Payment Terms:T/T, Western Union,
Place of Origin:China
Contact Now

Add to Cart

Verified Supplier
Address: Rm. 1203-1, Bldg. B, Xian Xinsilu International E-Commerce Industrial Park, No. 9, Gangwu Road, Int'l Port District
Supplier`s last login times: within 38 hours
Product Details Company Profile
Product Details

Production Description Original imported Economical compressed air CS VA500 flow meter with RS485


Display shows 2 values at the same time:

•Actual flow in m³/h, l/min,...
•Total consumption (counter reading) in m³, l
•resp. temperature measurement

Values indicated in the display turnab- le by 180°C, e.g. in case of overhead installation


Detailed Images Original imported Economical compressed air CS VA500 flow meter with RS485



Specification Original imported Economical compressed air CS VA500 flow meter with RS485


TECHNICAL DATA VA 520
Parameters:m³/h, l/min (1000 mbar,20 °C) at compressed air,or Nm³/h, Nl/min (1013,.mbar, 0 °C) for gases
Units adjustable via keys at display:m³/h, m³/min, l/min, l/s, ft/ min, cfm, m/s, kg/h, kg/min, g/s, lb/min, lb/h
Sensor:Thermal mass flow sensor
Measuring mediumAir, gases
Gas types are adjus- table over CS service

Air, nitrogen, argon, heli-

um, CO2, oxygen, vacuum

Measure range:See table
Accuracy:
(m.v.: of meas. value) (f.s.: of full scale)
± 1.5 % of m.v. ± 0.3 % of f.s. on request
± 1.0 % of m.v. ± 0.3 % of f.s.
Operating temperature:-30...80 °C
Operating pressure:-1 to 16 bar optional to
PN 40
Digital output:RS 485 interface (Modbus-RTU), Optional:
Ethernet-Interface PoE), M-Bus
Analog output:4...20 mA for m³/h e. g. l/min;
Pulse output:1 Pulse per m³ or per liter galvani- cally isolated. Pulse value can be set on the display. Alternatively, the pulse output can be
used as an alarm relay
Supply:18...36 VDC, 5 W
Burden:< 500 K
Housing:Polycarbonate (IP 65)
Measuring section:stainless steel, 1.4301 or 1.4571
Process connection:Flange (to DIN EN 1092-1e. g. ANSI 150 Ibs or ANSI 300 Ibs)
Ø Casing:65 mm
Mounting position:any

Features Original imported Economical compressed air CS VA500 flow meter with RS485


Easy installation in existing piping through integrated measuring sec-
tion (1/4” to 2“)
High measuring accuracy due to defined measuring section (inlet and outlet section)
•Digital interfaces such as Modbus RTU, Ethernet (PoE) and M-Bus enable connection to higher-level systems such as energy ma- nagement systems, building management systems, SPS,...
•Easy and auordable installation
•Units freely selectable via keys at the display m³/h, m³/min, l/min, l/s, kg/h, kg/min, kg/s, cfm
•Compressed air counter up to 1.999.999.999 m³. Resetable to „zero“ via keypad
•Analogue output 4...20 mA, pulse output (galvanically separated)
•High measuring accuracy also in the lower measuring range (ideal for leakage measurement)
•Negligibly small loss of pressure
•Calorimetric measuring principle, no additional pressure and temperature measurement necessary, no mechanically moved parts
•Comprehensive diagnosis functions can be read out at the display or by remote access via Modbus-RTU like e. g. exceeding Max./ Min values °C, calibration cycle, error codes, serial number. All parameters can be read out and changed via Modbus



Applications Original imported Economical compressed air CS VA500 flow meter with RS485


Compressed air flow and distribution
Flow and distribution of process gases such as carbon dioxide, hydrogen, nitrogen, oxygen flow
Explosive gases such as natural gas, hydrogen, biogas
Corrosive gases such as biogas
Fuel and gas supply in furnaces, boilers, industrial furnaces
gas in cooler
Gas injection metering control


Selection Guide Original imported Economical compressed air CS VA500 flow meter with RS485



China Economical Flowmeter 4-20mA RS485 DN15~DN80 Pipeline Gas Flowmeter CS VA520 supplier

Economical Flowmeter 4-20mA RS485 DN15~DN80 Pipeline Gas Flowmeter CS VA520

Inquiry Cart 0