Home /

110mm Measuring Guedel Oropharyngeal Airway X Large Adult

110mm Measuring Guedel Oropharyngeal Airway X Large Adult

Brand Name:AVACARE
Certification:ISO13485, CE0123
Model Number:110mm
Minimum Order Quantity:2000 units
Delivery Time:20-30 working days
Payment Terms:L/C, T/T
Contact Now

Add to Cart

Verified Supplier
Supplier`s last login times: within 48 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details
PVC Medical Grade 110mm airway bite block and designed for X-large Adult, Berman Orapharyngeal Airway

Basic Introduction:


HENAN AILE INDUSTRIAL CO., LTD is a company for operating medical disposables, and the Orapharyngeal Airway, which has smooth airway and Color-coded bite block, is one of our productions.


The oropharyngeal airway, also known as the oropharyngeal airway, is a non-tracheal tube non-invasive ventilation tube that can prevent the tongue from falling back, quickly open the airway, and establish a temporary artificial airway.


Guedel oropharyngeal airway, also known as Guedel airway or Guedel tube, is a medical device used to maintain an open airway in unconscious or sedated patients. It is commonly used during anesthesia administration, resuscitation, and in emergency situations.


The Guedel airway is a rigid plastic tube with a curved shape that is inserted into the patient's mouth and extends into the oropharynx. It is designed to prevent the tongue from obstructing the airway and to facilitate the passage of air and gases. The device has a flange or bite block at the proximal end, which helps to keep it in place and prevents it from being inserted too far into the patient's mouth.



The Guedel airway is available in various sizes to accommodate different patient age groups, ranging from infants to adults. The correct size is chosen based on the patient's anatomical characteristics, such as the distance from the corner of the mouth to the angle of the jaw.


To insert a Guedel airway, the patient's head is placed in a neutral position, and the mouth is opened. The device is inserted gently, with the curved tip facing the roof of the mouth. Once in place, it helps to keep the patient's tongue forward, preventing it from blocking the airway and allowing for easier ventilation.


It is important to note that the Guedel airway does not protect the patient's airway from aspiration of fluids or solids. Therefore, it should not be used in patients with a gag reflex or in situations where the patient is at risk of vomiting. Additionally, proper monitoring and frequent assessment of the patient's airway are essential when using the Guedel airway to ensure its effectiveness and patient safety.


As always, healthcare professionals should be consulted for proper insertion, sizing, and use of the Guedel oropharyngeal airway, as well as for any specific guidance or protocols in their clinical setting.



How to use Guedel Oropharyngeal Airway?


To use a Guedel oropharyngeal airway, follow these general steps:


Select the appropriate size: Choose the size of the Guedel airway based on the patient's age and anatomical characteristics. The airway should be long enough to reach from the corner of the mouth to the angle of the jaw without being inserted too deeply.


Prepare the patient: Position the patient's head in a neutral position, aligning the oral, pharyngeal, and tracheal axes. Open the patient's mouth by using a tongue depressor or jaw thrust technique if necessary.


Lubricate the airway: Apply a water-based lubricant to the Guedel airway to facilitate smooth insertion.


Insert the airway: Hold the Guedel airway with the curved tip facing upwards. Insert the airway into the mouth, following the natural curve of the tongue. Gently advance the airway along the roof of the mouth until it reaches the back of the throat (oropharynx). Avoid forcing or causing any trauma during insertion.


Rotate the airway: Once the airway is fully inserted, rotate it 180 degrees so that the curved tip faces downwards, resting against the soft palate. This helps prevent the tongue from blocking the airway.


Confirm proper placement: Ensure that the Guedel airway is not inserted too deeply or not deep enough. The flange or bite block of the airway should sit just outside the patient's lips, and the patient's teeth should be positioned between the bite block and the airway shaft.


Secure the airway: If necessary, secure the Guedel airway in place by using medical tape or other appropriate methods. This helps prevent accidental dislodgement.


Monitor the patient: Continuously monitor the patient's airway, breathing, and oxygenation. Observe for any signs of airway obstruction or complications.


Remember, the use of the Guedel oropharyngeal airway should be performed by trained healthcare professionals who are familiar with airway management techniques. It is important to follow institutional guidelines and protocols specific to your clinical setting.


Product compositions:

  • The Berman Orapharyngeal Airway has110mm smooth airway.
  • It also has two sides channe.

110mm Berman Orapharyngeal Airway Application Features:

  1. Atraumatic one piece design for optimum patient comfort and safety.
  2. Rigid bite block to ensure airway patency.
  3. Two sides channel design provides passage of suction catheter to clear secretions and also provides space for oral care.
China 110mm Measuring Guedel Oropharyngeal Airway X Large Adult supplier

110mm Measuring Guedel Oropharyngeal Airway X Large Adult

Inquiry Cart 0