E Type Straight Clinic Slow Speed Dental Handpiece 20000rpm

Brand Name:DORIT
Certification:ISO CE FDA
Model Number:DR-W11S
Minimum Order Quantity:2 piece
Delivery Time:5-8 work days
Payment Terms:L/C, D/A, D/P, T/T, Western Union, Paypal
Contact Now

Add to Cart

Verified Supplier
Location: Zhengzhou China
Address: NO11,Changchun Road, Hi-tech Zone Zhengzhou,China
Supplier`s last login times: within 26 hours
Product Details Company Profile
Product Details

E-Type Straight Slow Speed Dental Clinic Handpiece


External Straight Handpiece Quick view


Parameter:
Air pressure:245-392kPa
Atomized water pressure:200kPa
Water consumption: 50ML/min
Atomized air pressure:200kPa
Air consumption: 1.5L/min
Rotation Speed:14000-20000r/min
E-type connect, Forward & Reverse
Noise :≤70dB


External Straight Handpiece Advantage

Product name1:1 low speed straight handpiece
Torque3.0N
ColorSilver
Working air pressure0.3~0.35 Mpa
Max speed22,000rpm
Noise≤70dB
Speed ratio1:1
ConnectorE-type air motor
Bearingceramic bearing
Water sprayexternal water spray
Warranty Period1 year

Why Choose Us



Henan Dorit Biotechnology Co., Ltd is located in the National University Science Park of Hi-Tech Development Zone, Zhengzhou, Henan Province. Henan Dorit specialize in dental treatmen equipment area, main product contains high or low speed dental handpiece, ultrasonic scaler, three-way syringe and Dental LED Curing light.

Low speed dental handpiece are mainly used to wear dentures, polished and planted. Divided into straight and bending machine.

High Speed dental handpiece mainly used to do treatment and repair more (such as holes, cutting).

All our product with CE, TUV, FDA certification, some areas can provide sample service, if you need, pls contact us anytime.


After each treatment,Sterilizing handpiece in autoclave according to the following steps:

1.Remove the bur and brush clean handpiece, clean outside of handpiece with an alcohol solution.

2.Lubricate handpiece, each times drop two drops inside of air inlet pipe.

3.Place into autoclaving pouch and mark.

4.Autoclave the handpiece for 12 min. at 135ºC.

Operation Instruction:

It shall be sterilized before handpiece is used at the first time;sterilization temperature is 135ºC and last for 12 minutes.

After using,Please follow the instruction to sterilize the handpiece:

1 extract the bur from the handpiece,use the soft brush to clean the dirt and wash with disinfection of alcohol cotton.

2 lubricate the handpiece,pour two drops into air tube one time.

3 wrap it with sterilization package and mark.