E Generator Dental LED High Speed Handpiece 2/4 Hole

Brand Name:DORIT
Certification:CE ISO FDA
Model Number:DR-161
Minimum Order Quantity:2pc
Delivery Time:5-7 working days
Payment Terms:Paypal, T/T, Western Union, MoneyGram
Contact Now

Add to Cart

Verified Supplier
Location: Zhengzhou China
Address: NO11,Changchun Road, Hi-tech Zone Zhengzhou,China
Supplier`s last login times: within 26 hours
Product Details Company Profile
Product Details

High Speed Dental Handpieces E-Generator Dental LED

High Speed Handpiece 2/4 Hole


High Speed Handpiece Led Features:


The DORIT LED high speed handpiece & swivel with inbuilt generator creates LED light in the mouth.

Simple FG bur changing

Precision bur cooling – triple coolant spray produces a mist around the bur.

Patented hygienic head – Prevents aerosol particles from being sucked into the turbine.

1 year warranty.


High Speed Handpiece Led Tech data:

Product nameHigh Speed Handpiece Led
Drive air pressure0.25-0.3Mpa
Water pressure0.2Mpa
Water pressure198Kpa(2kg)
Light brightness25500lux
Power22W
Rotation speed350,000~420,000rpm
Head height13.0mm
Head diameterΦ11mm
Chuck typePush button
Clamping force22N~34N
Torque force0.1N·cm(small head); ≥0.1N·cm(large head)
Bur ApplicableΦ1.59mm-Φ1.60mm*21mm-23mm(diameter*length)
Noise≤60DB

High Speed Dental Handpiece Led Detailed photos:



After each patient use , maintenance should be done as follows:


1. First remove the diamond burs , and clean up all the teeth on dental handpieces precipitate

2. Use a metal needle to clean the spray holes and fumaroles

Note: The spray holes and diamond burs into 40 -degree angle , fumaroles and diamond burs to a 30 degree angle

3. Place the clean lubricating oil is sprayed into the axial hole 1-2 seconds ( diamond burs is plugged holes )

4. In the bottom of the handpiece were ( with / without quick connector ) two kinds of styling , make the right amount of lubricant is injected into the bottom

5. The handpiece with quick connector combination ( first determine the water switch is turned off )

6. Replace the diamond burs , surrounded by white silk cloth handpiece head ( make sure the needle does not touch the diamond burs and white gauze , so as not to tie )

7. pedal depressed for about 20 seconds , look at whether there is in white gauze on any stain. If there are stains on the white gauze , again, add oil , starting from item 4 continued routine maintenance , know that white gauze until no stain

8. Finally, no more than 135 degrees Celsius temperature and high pressure sterilization