High Speed Triple Spray 2 Hole 4 Hole Dental Handpiece Standard Torque Head

Brand Name:DORIT
Certification:ISO, CE, FDA
Model Number:DR-163
Minimum Order Quantity:2piece
Delivery Time:5-8 work days
Payment Terms:L/C, D/A, D/P, D/P, Western Union, MoneyGram,Paypal
Contact Now

Add to Cart

Verified Supplier
Location: Zhengzhou China
Address: NO11,Changchun Road, Hi-tech Zone Zhengzhou,China
Supplier`s last login times: within 26 hours
Product Details Company Profile
Product Details

Standard Head/Torque Head High Speed Triple Spray

2 Hole 4 Hole Dental Handpiece


Advantage


1. Chinese ceramic ball bearing; open style cartridge.

2. Triple spray, effective cooling for bur and treating contact surface.

3. Push button type to change bur, easy and convenient.

4. sterilized in 135℃ to avoid cross-infection.

5. Streamlined design, comfortable for hand feeling, easy to clean.


Technical Data


Type

Triple spray


3 way spray 3 air

2 hole / 4 hole

2 hole / 4 hole

2 hole / 4 hole


Model

Standard, torque

LED Type

Led-generator

Chuck typePush button
Noise≤60dB
Head Diameter
Φ12.5mm(torque)/ Φ10.8mm(standard)
Bur applicable
Φ1.59mm-Φ1.60mm*21mm-23mm(diameter*length)
Rotation speed
300,000~350,000rpm(Torque); 350,000~420,000rpm(Standard)
Head height13.1mm(Torque)/13.0mm(Standard)
Power22W(standard); 25W(torque)
Light brightness25500lux

Steps for disinfection of dental turbine handpieces


1. First remove the diamond burs , and clean up all the teeth on dental handpieces precipitate

2. Use a metal needle to clean the spray holes and fumaroles

Note: The spray holes and diamond burs into 40 -degree angle , fumaroles and diamond burs to a 30 degree angle

3. Place the clean lubricating oil is sprayed into the axial hole 1-2 seconds ( diamond burs is plugged holes )

4. In the bottom of the handpiece were ( with / without quick connector ) two kinds of styling , make the right amount of lubricant is injected into the bottom

5. The handpiece with quick connector combination ( first determine the water switch is turned off )

6. Replace the diamond burs , surrounded by white silk cloth handpiece head ( make sure the needle does not touch the diamond burs and white gauze , so as not to tie )

7. pedal depressed for about 20 seconds , look at whether there is in white gauze on any stain. If there are stains on the white gauze , again, add oil , starting from item 4 continued routine maintenance , know that white gauze until no stain

8. Finally, no more than 135 degrees Celsius temperature and high pressure sterilization