IQS900 204-900-000-011 Signal Conditioner Proximity Measurement System

Brand Name:Other Brands
Certification:CO
Model Number:IQS900 204-900-000-011
Minimum Order Quantity:1EA
Delivery Time:5-8 working days
Payment Terms:T/T
Contact Now

Add to Cart

Verified Supplier
Location: Xiamen Fujian China
Address: Unit 1602, Top Plaza, No.2 Lujiang Road, Siming District, Xiamen Fujian China
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details

IQS900 204-900-000-011 Signal Conditioner Proximity Measurement System


Product Details:


Brand NameOthers
ModelIQS900
Ordering information204-900-000-011
ConditionNew
Gross Weight/Shipping Weight2.2 lbs / 35.2 oz / 1kg
Packing Size6.4" x 6.4" x 4.8" (16cm x 16 cm x 12 cm)
Country of Origin/Original CountryChina
Lead TimeIn Stock
Shipping PortXiamen
PaymentT/T
Sales PriceInquiry
ColorDepends on material
Warranty12 months
Lead time5-8 work days
Courier partnersDHL, UPS, TNT, FedEx and EMS


Additional Information:


N/MN/M


Description:


The IQS900 signal conditioner contains a highfrequency modulator/demodulator that supplies a driving signal to the transducer. This generates the necessary electromagnetic field used to measure the gap. The conditioner circuitry is made of high-quality components and is mounted in a painted aluminium housing.


The IQS900 should be powered (energised) using a limited-power, low-voltage power supply such as a sensor power supply output provided a monitoring and/or protection system, galvanic separation unit or other suitable power supply. In safety-related applications, an IQS900 must be powered using a limited-power, low-voltage power supply with a safe limitation of −30 VDC (nominal), even in the event of a single fault with the power supply.


Voltage at min. / max. gap : −1.6 V / −17.6 V

Measurement range : 16 V (corresponding to 12 mm)

Output sensitivity : See Operation on page 2 and IQS900 signal conditioner

Nominal output signal

• Without diagnostics : −1.6 t o −17.6 V

• With diagnostics : −1.6 t o −17.6 V indicates normal operation. Other current values (>−1.6 or <−17.6 V) indicate a problem with the measurement chain (sensor, cabling and/or signal conditioner).