Field devices equipped with only a single PROFIBUS DP interface, can be integrated in the redundant PROFIBUS network by using the Redundancy Link Module RLM01. Acting like an active switch, it converts two redundant lines to one PROFIBUS DP line or vice versa. The RLM01amplifies signal form and amplitude of the incoming data and monitors activities and error statuses of all three lines.
The RLM01 module can be positioned directly next to a master, in
front of a bus segment with several slaves, or in front of an
individual slave. Several PROFIBUS stations with redundant couplers
can be connected directly to the PROFIBUS that has been made
redundant by RLM01. Stations with just one interface can be
positioned either on the A line or on the B line. Each RLM01
PROFIBUS interface can operate up to 31 PROFIBUS stations.
Line redundancy:
The module reinforces die signal form and amplitude of the data
received and monitors all three lines with regard to activity and
faults. Any faults that are recognized are indicated with the aid
of a LED on the front panel. Suitable messages are available for
diagnostic purposes and can be picked up on the 8-pole terminal
strip.
Combining redundant lines:
The data that arrives first via line A or line B (see the diagram
above), with the correct start of frame, is forwarded to connection
M. If the data arrives at the same time, either line A or line B is
selected at random. If an error is detected at line A, the control
logic switches to line B, which is still available. The procedure
is the same in reverse for line B.
Splitting a non-redundant line:
Data arriving via line M with the correct start of frame is passed
in parallel to the other two connections, A and B. If the start of
frame is incorrect, the control logic does not output any data at A
and B.
For increased availability of the RLM 01 itself, a redundant power
supply with 24 V d.c. can be connected. The monitoring logic checks
whether both voltages are available and reports any malfunction
that may occur.