8BVP0880HC00.004-1 B&R PLC ACOPOSmulti Power Supply Module


MATERIAL NUMBER:

8BVP0880HC00.004-1

DESCRIPTION:
  • Extensive input voltage range
  • Capable of regeneration
  • Integrated connection for temperature sensors
  • 2 slots for ACOPOSmulti plug-in modules

ACOPOSmulti power supply module, 88 A, AS, cold plate or pass-through mounting


General information
B&R ID code0xA6A1
Cooling and mounting typeCold plate or pass-through mounting
Slots for plug-in modules2
Certifications
CEYes
ULcULus E225616
Power conversion equipment
EACYes
KCYes
Mains connection
Network configurationsTT, TN-S, TN-C-S
Mains input voltage3x 220 to 3x 480 VAC ±10%
Frequency50 / 60 Hz ±4%
Installed loadMax. 62 kW
Inrush current at 400 VACMax. 133 A
Switch-on interval>300 s
Max. DC bus capacitance depending on mains voltage
230 VAC34.8 mF
400 VAC11.5 mF
480 VAC8 mF
Nominal switching frequency5 kHz
Possible switching frequencies5 / 10 kHz
Integrated line filter per EN 61800-3, category C3No
Integrated regeneration chokeNo
RegenerativeYes
Power factor correction (PFC)Yes
Variant
L1, L2, L3, PEM8 threaded bolts
Shield connectionYes
Connection cross section range
Flexible and fine-stranded wires---
Terminal cable cross section dimension of shield connection32 to 50 mm
DC bus connection
Voltage
Nominal750 VDC
Continuous power (supply and regeneration)60 kW
Reduction of continuous power depending on mains input voltage
Mains input voltage <3x 400 VAC150 W/V * (400 V - Mains input voltage)
Reduction of continuous power depending on DC bus voltage (UDC)
UDC <750 VDC0.08 kW/V
Reduction of continuous power depending on switching frequency and mounting type
Switching frequency 5 kHz
Cold plate mounting1.3 kW/K (starting at 58°C)
Pass-through mountingIn preparation
Switching frequency 10 kHz
Cold plate mounting0.95 kW/K (starting at 27°C)
Pass-through mountingIn preparation
Reduction of continuous power depending on installation elevation
Starting at 500 m above sea level6 kW per 1000 m
Peak power (supply and regeneration)120 kW
Power dissipation depending on switching frequency
Switching frequency 5 kHz[0.065*P²+11.4*P+90] W
Switching frequency 10 kHz[0.22*P²+16.1*P+185] W
DC bus capacitance1650 µF
Protective measures
Overload protectionYes
Short-circuit and ground fault protectionNo
VariantACOPOSmulti backplane
24 VDC power supply
Input voltage25 VDC ±1.6%
Input capacitance4.7 µF
Max. power consumption27 W + PSLOT1 + PSLOT2 + P24 V Out + PFan8BVF...
VariantACOPOSmulti backplane
24 VDC Out
Quantity2
Output voltage
DC bus voltage (UDC): 260 to 315 VDC25 VDC * (UDC / 315)
DC bus voltage (UDC): 315 to 800 VDC24 VDC ±6%
Fuse protection250 mA (slow-blow) electronic, automatic reset
Filter fan connection
Output voltage24 V +5.8% / -0.1%
Continuous current4.2 A
Max. overcurrent limiting10 A
Protective measures
Overload protectionNo
Short-circuit proofYes
Open-circuit monitoringNo
Undervoltage monitoringNo
Trigger inputs
Quantity2
CircuitSink
Electrical isolation
Input - Power supply moduleYes
Input - InputYes
Input voltage
Nominal24 VDC
Maximum30 VDC
Switching threshold
Low<5 V
High>15 V
Input current at nominal voltageApprox. 10 mA
Switching delay
Rising edge52 μs ±0.5 μs (digitally filtered)
Falling edge53 μs ±0.5 μs (digitally filtered)
Modulation compared to ground potentialMax. ±38 V
Electrical properties
Discharge capacitance0.9 µF
Operating conditions
Permissible mounting orientations
Hanging verticallyYes
Horizontal, face upYes
Standing horizontallyNo
Installation elevation above sea level
Nominal0 to 500 m
Maximum4000 m
Pollution degree per EN 61800-5-12 (non-conductive pollution)
Overvoltage category per EN 61800-5-1III
Degree of protection per EN 60529IP20
Ambient conditions
Temperature
Operation
Nominal5 to 40°C
Maximum55°C
Storage-25 to 55°C
Transport-25 to 70°C
Relative humidity
Operation5 to 85%
Storage5 to 95%
TransportMax. 95% at 40°C
Mechanical properties
Dimensions
Width213.5 mm
Height317 mm
Depth
Cold plate212 mm
Pass-through mounting209 mm
WeightApprox. 7.9 kg
Module width4