VICTOR 07 Temperature Calibrator Multi-function process calibrator thermocouple calibrator

Brand Name:VICTOR
Certification:CE
Model Number:VICTOR 07
Minimum Order Quantity:1pcs
Delivery Time:5 to 30 days
Payment Terms:T/T, Western Union, L/C, Paypal
Contact Now

Add to Cart

Site Member
Address: JINGYUAN 7 ROAD, JINGHE INDUSTRIAL PARK, NORTH DISTRICT,XI'AN,CHINA  710200
Supplier`s last login times: within 22 hours
Product Details Company Profile
Product Details

VICTOR 07 Temperature Calibrator Multi-function process calibrator thermocouple calibrator


Introduction

Temperature calibrator (hereinafter referred to as calibrator) is a hand-held portable instrument powered by battery and capable of measuring and outputting electrical and physical parameters. Can be used for measuring DC voltage, DC current, resistance, thermocouple and thermal resistance; And simulating output DC voltage, DC current, resistance, thermocouple, thermal resistance.


Measurement functionRangeMeasuring rangeResolutionAccuracyRemarks

DC Voltage

DCV

100mV-110.000mV~110.000mV0.001mV0.05%+0.03mVInput resistance: Approximately 1MΩ
1V-1.1000V~1.1000V0.0001V0.05%+0.3mV
35V-35.000V~35.000V0.001V0.02%+2mV

DC current

DCI

30mA-35.000mA~35.000mA0.001mA0.02%+4uA

Shunt resistance: Approximately 10Ω

Input resistance: Approximately 20Ω

Resistance

OHM

500Ω0~550.00Ω0.01Ω0.05%+0.2Ω

2W/3W/4W measurement

500Ω~1mA excitation

5KΩ~0.1mA excitation

Open circuit voltage: Approximately 2.5V

Lead resistance is not included in measurement accuracy

5KΩ0~5.5000KΩ0.0001KΩ0.05%+2Ω

Thermocouple

TC

R0°C~1767°C1°C

0~500℃

500~1767℃

2.5℃

2℃

Use ITS-90 temperature scale

Error of cold junction compensation is not included in accuracy

Sensor inaccuracy not included in accuracy

The effect of thermoelectric potential is not included in the accuracy

The corresponding materials of the left division number are as follows:

R: Platinum rhodium 13-Platinum

S: Platinum rhodium 10-Platinum

K: Nickel chromium-Nickel silicon

E: Nickel chromium-Copper nickel (Constantan)

J: Iron-Copper nickel (Constantan)

T: Copper-Copper-nickel (Constantan)

N: Nickel chromium silicon-Nickel silicon

B: Platinum rhodium 30-Platinum

A: Tungsten rhenium 5-Tungsten-rhenium 20

C: Tungsten rhenium 5-Tungsten-rhenium 26

D: Tungsten rhenium 3-Tungsten-rhenium 25

S0°C~1767°C
K-100.0°~1372.0°C0.1°C

-100.0~0.0℃

0.0~1372.0℃

1.2℃

0.8℃

E-50.0°C~1000.0°C

-50.0℃~0.0℃

0.0~1000.0℃

0.9℃

1.5℃

J-60.0°C~1200.0°C

-60.0~0.0℃

0.0~1200.0℃

1.0℃

0.7℃

T-100.0°C~400.0°C

-100.0~0.0℃

0.0~400.0℃

1.0℃

0.7℃

N-200.0°~1300.0°C

-200.0~0.0℃

0.0~1300.0℃

1.5℃

0.9℃

B600°C~1820°C1°C

600~800℃

800~1000℃

1000~1820℃

2.2℃

1.8℃

1.4℃

A0°C~2500°C1°C

0~1600℃

1600~2000℃

2000~2500℃

2.0℃

2.2℃

2.4℃

C0°C~2310°C1°C

0~1600℃

1600~2000℃

2000~2310℃

2.0℃

2.2℃

2.4℃

D0°C~2310°C1°C

0~100℃

100~270℃

270~1200℃

270~2310℃

2.6℃

2.4℃

2.2℃

2.4℃

Thermal resistance

RTD

(3W)

Pt100

385

-200.0°C~800.0°C0.1°C

-200.0~0.0℃

0.0~400.0℃

400.0~800.0℃

0.5℃

0.7℃

0.8℃


Use Pt (385) temperature scale

2W/3W/4W measurement

500Ω~1mA excitation

5KΩ~0.1mA excitation

Open circuit voltage: Approximately 2.5V

Errors introduced by 2W/3W measurement lead resistance mismatch are not included in accuracy

Sensor inaccuracy not included in accuracy

The effect of thermoelectric potential is not included in the accuracy

Pt200

385

-200.0°C~630.0°C

-200.0~100.0℃

100.0~300.0℃

300.0~630.0℃

0.8℃

0.9℃

1.0℃

Pt500

385

-200.0°C~630.0°C

-200.0~100.0℃

100.0~300.0℃

300.0~630.0℃

0.4℃

0.5℃

0.7℃

Pt1000

385

-200.0°C~630.0°C

-200.0~100.0℃

100.0~300.0℃

300.0~630.0℃

0.3℃

0.5℃

0.7℃

Cu50-50.0°C~150.0°C-50.0~150.0℃0.7℃
Continuity detection500Ω≤ 50Ω will sound0.01ΩApproximately 1mA excitation

Loop power supply

LOOP

24 V10%

China VICTOR 07 Temperature Calibrator Multi-function process calibrator thermocouple calibrator supplier

VICTOR 07 Temperature Calibrator Multi-function process calibrator thermocouple calibrator

Inquiry Cart 0