VICTOR 26 Multifunction Process Calibrator Signal Generator With Accuracy Of 0.01% 5 Digits Display 24V loop circuit IP65

Brand Name:VICTOR
Certification:CE
Model Number:VICTOR 26
Minimum Order Quantity:1pcs
Delivery Time:5 to 30 days
Payment Terms:T/T, Western Union, L/C, Paypal
Contact Now

Add to Cart

Site Member
Address: JINGYUAN 7 ROAD, JINGHE INDUSTRIAL PARK, NORTH DISTRICT,XI'AN,CHINA  710200
Supplier`s last login times: within 22 hours
Product Details Company Profile
Product Details

VICTOR26 Multifunction Process Calibrator Signal Generator With Accuracy Of 0.01% 5 Digits Display 24V Loop Circuit IP 65 Protection Grade

  • Basic feature
  • A multifunctional on-spot process calibrator with high accuracy and high stability, which can provide powerful measurable functions, output and calibrates all parameters for all kinds of process.
  • Basic feature of input measurement
  • The max accuracy of measurement can reach 0.01%, and displays as 5 digits.
  • Measurement functions include: DC voltage, DC current, resistance, RTD, TC, frequency, pulse counting, switch volume, pressure, and pressure leakage ect.
  • Undertake two-wired, three-wired and four-wired resistance and RTD measurement.
  • Switch test of fast response allows capturing the process parameters for switching actions.
  • Data settle function: data-holding, zero, proportion, mean, Max/min value ect.
  • Built-in 24V loop circuit and loop current measurement
  • Basic feature of analog output
  • Max accuracy of output can reach 0.01%, and output displays as 6 digits.
  • Output functions include: DC voltage, DC current, analog resistance, RTD, TC, analog transmitter output, frequency, pulse counting, switch volume, and pressure output ect.
  • Output augment and decrease setting, and can connect or disconnect output, which is easy for operation.

DCI output manual-step, auto-step and auto-ramping output functions.

Built-in 24V loop circuit.

  • Two independent channels for measurement and input, allowing in-time measurement and outputs of process signals simultaneously; multiple data display to display input measurement value and output settings.
  • Facilitate pressure calibration by external a series of VPM-S digital pressure module through serial RS-232 injection (LEMO plug). There are abundant varieties and range specification of pressure modules to meet any pressure measurement needs. And the basic accuracy can reach 0.05%, and a variety of pressure units are available for pressure calibration.
  • Provide varieties of selectable temperature graduation. Built-in accurate temperature transmitter, with high accurate TC cold-compensation function, and RTD cold compensation can be selected both for connection or disconnection.
  • PC on-line communication function
  • The meter provides two ways to communicate with the user’s upper PC and can communicate by the infrared isolated serial commutation module of the compatible USB interface.
  • Supports SCPI commands of industrial standard, and can realize remote control of the meter by equipment driving software.
  • Note: the PC communication function is not available when the meter is communicating with the pressure module in HART communication function.
  • The meter is equipped with data storage with large capacity, to store as many as 1000(groups) data of field calibration. The data can be read from the meter or uploaded to the user’s PC.
  • The meter employs panel calibration technique, connects to standard device, undertakes panel calibration operation according to set range, and saves relevant calibrated data, fulfills the periodic calibration work stipulated by the meter to ensure the accuracy and performance.
  • The meter employs the navigation key to make increment or decrement of the setting value, which makes operation convenient and easy.
  • 3.2 inches TFT display screen, supporting multiple data display and intuitive interface.
  • Other functions: auto power-off, VF, auto turn- off for backlight, setting of backlight, data and time display and setting, ambient temperature detection, power frequency setting ect.
  • two ways of power supply
  • The instrument can supply power through the four 5th alkaline batteries in the battery case, or use the adaptor to supply.
  • Basic functions and performance(technical index)

Input Measurement Function [adapt to one year after calibration 23℃±5℃,20~70% RH,accuracy=±(% readings + % range)]

measurement functionrangemeasurement rangeresolutionaccuracyremark

DC voltage

DCV

50mV

-5.000mV~

55.000mV

1μV0.01+0.01Input resistance: about 100MΩ
500mV

-50.00mV~

550.00mV

10μV0.01+0.01
5V

-0.5000V~

5.5000V

0.1mV0.01+0.01Input resistance: about 1MΩ
30V

-5.000V~

35.000V

1mV0.01+0.01

DC current

DCI

50mA

-5.000mA~

55.000mA

1μA0.01+0.01shunt resistance: about 10Ω

Ohms

OHM

(4W)

500Ω0.00Ω~550.00Ω0.01Ω0.01+0.01

500Ω about 1mA simulation

5KΩ about 0.1mA simulation

open-loop voltage: about 2.5V

wire resistance is excluded in the accuracy

5KΩ

0.0000 KΩ~

5.5000KΩ

0.1Ω0.01+0.01

frequency

FREQ

50KHz3Hz~50.00000KHz0.01Hz0.01+0.00004

input resistance: more than 100 kΩ

frequency sensitivity:

square wave is 3V Vp-p at least

50% duty ratio

CPM180~3000000 CPM1CPM±2个字

Thermal couple

TC

R*0°C~1767°C1°C

0~500℃ : 1.8℃

500~1767℃ : 1.5℃

Employ ITS-90 temperature standard

Errors for cold-end compensation is excluded in the accuracy

S*0°C~1767°C
K-100.0°~1372.0°C0.1°C

-100.0~0.0℃ : 1.2℃

0.0~1372.0℃ : 0.8℃

E-50.0°C~1000.0°C

-50.0℃~0.0℃ : 0.9℃

0.0~1000.0℃ : 1.5℃

J-60.0°C~1200.0°C

-60.0~0.0℃ : 1.0℃

0.0~1200.0℃ : 0.7℃

T-100.0°C~400.0°C

-100.0~0.0℃ : 1.0℃

0.0~400.0℃ : 0.7℃

N-200.0°~1300.0°C

-200.0~0.0℃ : 1.5℃

0.0~1300.0℃ : 0.9℃

B*600°C~1820°C1°C

600~800℃ : 2.2℃

800~1000℃ : 1.8℃

1000~1820℃ : 1.4℃

L-60.0°C~900.0°C0.1°C

-60.0~0.0℃ 0.7℃

0.0~900.0℃ 0.5℃

U-100.0°C~600.0°C0.1°C

-100.0~0.0℃ 0.7℃

0.0~600.0℃ 0.5℃

Resistance temperature

RTD


Pt100

385

-200.0°C~800.0°C0.1°C

-200.0~0.0℃ : 0.5℃

0.0~400.0℃ : 0.7℃

400.0~800.0℃ : 0.8℃

Employ ITS-90 temperature standard

Errors due to the mismatch of lead resistance for lead resistance, 3-wired or 4-wired measurements are excluded in the accuracy

Pt1000

385

-200.0°C~630.0°C

-200.0~100.0℃: 0.3℃

100.0~300.0℃ : 0.5℃

300.0~630.0℃ : 0.7℃

Pt200

385

-200.0°C~630.0°C

-200.0~100.0℃: 0.8℃

100.0~300.0℃ : 0.9℃

300.0~630.0℃ : 1.0℃

Pt500

385

-200.0°C~630.0°C

-200.0~100.0℃: 0.4℃

100.0~300.0℃ : 0.5℃

300.0~630.0℃ : 0.7℃

Cu10-100.0°C~260.0°C1.8℃
Cu50-50.0°C~150.0°C0.7℃

Pulse counting

PULSE

100000 cycles1~100000cycles1cycle±2个字see the related indexes for frequency

switch volume measurement

SWITCH

CLOSE / OPEN

about 1mA simulation

short circuit displays CLOSE

open circuit displays OPEN

the threshold value is about 200~300Ω

Continuity test

CONNECT

500Ω≤ 50Ω vocalize0.01Ω

500Ω

about 1mA simulation

Loop supply

LOOP

24 V10%

short circuit protection

Max circuit : 22 mA

Max input voltage: 30 V DC

output resistance: 250Ω nominal value

Other features:

  • The valid temperatures of TC R, S, B range from 0 to 50°C when make manual compensation.
  • measurement speed ratio: twice / second
  • common mode rejection: 50Hz / 60Hz > 120 dB , series mode rejection: 50Hz / 60Hz > 60 dB
  • temperature coefficient: 0.1 x basic accuracy / ℃ (temperature range <18℃ or >28℃)
  • built-in temperature compensation transistor RJC, measuring range -10~50°C, the accuracy of measured temperature between 18 to 28°C is ±0. 5℃ , the accuracy of other measured temperature is ±1℃. Time for cold temperature is 10S/every time.
  • the Max voltage applied between V,Ω,Hz input terminals and COM terminals : 30Vpk
  • The maximum current of mA terminals: 100mA . mA input protection of mA terminals: 100mA/250V fast-melt.

Simulation Output Function [adapt to one year after calibration 23℃±5℃, 20~70%RH ,accuracy=±(% settings + range %)]

Output functionrangeOutput rangeresolutionaccuracyremark

DC voltage

DCV

100mV-10.000~110.000mV1μV0.01+0.01Max output current 0.5mA
1V-0.10000~1.10000V10μV0.01+0.01Max output current 2mA
10V-1.0000~11.0000V0.1mV0.01+0.01Max output current 5mA

Dc current

DCmA

30mA0.000~33.000mA1μA0.01+0.01

In 33mA,

the Max load is 1KΩ resistance

in simulate transmitter,external power supply 5~28V

Ohmn

OHM

400Ω0.00~400.00Ω0.01Ω0.01+0.01

simulate current is ±0.05~0.3mA

simulate current is ±0.1~0.5mA , plus 0.1Ω additional error

wire resistance is excluded in the accuracy

4KΩ0.0000~4.0000 KΩ0.1Ω0.01+0.01

±0.05~0.3mA simulate current

wire resistance is excluded in the accuracy

Thermal couple

TC

R*0°C~1767°C1°C

0~100℃

10~1767℃

0~100℃

100~1767℃

1.5℃

1.2℃

1.5℃

1.2℃

Employ ITS-90 temperature standard


Errors for cold-end compensation is excluded in the accuracy

S*0°C~1767°C
K-200.0°C~1372.0°C0.1°C

-200.0~-100.0℃

-100.0~400.0℃

400.0~1200.0℃

1200.0~1372.0℃

0.6℃

0.5℃

0.7℃

0.9℃

E-200.0°C~1000.0°C

-200.0~-100.0℃

-100.0~600.0℃

600.0~1000.0℃

0.6℃

0.5℃

0.4℃

J-200.0°C~1200.0°C

-200.0~-100.0℃

-100.0~800.0℃

800.0~1200.0℃

0.6℃

0.5℃

0.7℃

T-250.0°C~400.0°C-250.0~400.0℃0.6℃
N-200.0°C~1300.0°C

-200.0~-100.0℃

-100.0~900.0℃

900.0~1300.0℃

1.0℃

0.7℃

0.8℃

B*600°C~1820°C1°C

600~800℃

800~1820℃

1.5℃

1.1℃

L-200.0°C~900.0°C0.1°C

-200.0~0.0℃

0.0~900.0℃

0.7℃

0.5℃

U-200.0°C~600.0°C0.1°C

-200.0~0.0℃

0.0~600.0℃

0.7℃

0.5℃

resistance temperature

RTD

Pt100

385

-200.0°C~800.0°C0.1°C

-200.0~0.0℃

0.0~400.0℃

400.0~800.0℃

0.3℃

0.5℃

0.8℃

Employ ITS-90 temperature standard


Pt100,Cu50,Cu10 simulate current is: ±0.5~3mA

when the simulate current is : ±0.1~0.5mA, add additional 0.5℃ error.


Pt200,Pt500,Pt1000 simulate current is ±0.05~0.3mA

wire resistance is excluded in the accuracy

Pt200

385

-200.0°C~630.0°C

-200.0~100.0℃

100.0~300.0℃

300.0~630.0℃

0.8℃

0.9℃

1.0℃

Pt500

385

-200.0°C~630.0°C

-200.0~100.0℃

100.0~300.0℃

300.0~630.0℃

0.4℃

0.5℃

0.7℃

Pt1000

385

-200.0°C~630.0°C

-200.0~100.0℃

100.0~300.0℃

300.0~630.0℃

0.2℃

0.5℃

0.7℃

Cu10-10.0°C~250.0°C1.8℃
Cu50-50.0°C~150.0°C0.6℃

frequency

FREQ

100Hz1.00 Hz ~110.00Hz0.01Hz±2 bytes

1~11 Vp-p accuracy of square wave level

±5%reading +0.5V

50% duty ratio

load >100KΩ

1KHz0.100 KHz ~1.100KHz1Hz±2 bytes
10KHz1.0KHz~11.0KHz0. 1KHz±2 bytes
50KHz10KHz~50KHz2KHz±5 bytes
CPM60~1200 CPM1CPM±2CPM

Pulse counting

PULSE

100Hz1~100000cycles1cyc±2 bytessee related index in frequency
1KHz
10KHz

Switch volume

SWITCH

100Hz1.00Hz~110.00Hz0.01Hz±2 bytes

see related index in frequency

FET switch

Max switch DC voltage/current: +28 V/50mA

1KHz0.100KHz~1.100KHz1Hz
10KHz1.0KHz~11.0KHz0.1KHz
50KHz10KHz~50KHz2KHz
Techincal Data
ProjectModel
Performance
parameters
VICTOR 26VICTOR 26H
SourceDC millivoltRange-5 ~ 110mV-5 ~ 110mV
Accuracy=
±(% of the set value+% of range)
0.01%+0.01%0.01%+0.01%
Resolution1uV1uV
DC voltageRange-1 ~ 11V-1 ~ 11V
Accuracy=
±(% of the set value+% of range)
0.01%+0.01%0.01%+0.01%
Resolution10uV/0.1mV10uV/0.1mV
DC currentRange0 ~ 33mA0 ~ 33mA
Accuracy=
±(% of the set value+% of range)
0.01%+0.01%0.01%+0.01%
Resolution1uA1uA
Sink currentRange0 ~ 33mA0 ~ 33mA
Accuracy=
±(% of the set value+% of range)
0.01%+0.01%0.01%+0.01%
Resolution1uA1uA
External power
supply
5 ~ 28V5 ~ 28V
ResistanceRange0 ~4KΩ0 ~4KΩ
Accuracy=
±(% of the set value+% of range)
0.01%+0.01%0.01%+0.01%
Resolution0.01Ω/0.1Ω0.01Ω/0.1Ω
ThermocoupleRangeR/S/K/E/J/T/B/N/L/UR/S/K/E/J/T/B/N/L/U
Accuracy0.4℃0.4℃
Resolution0.1℃/1℃0.1℃/1℃
RTDRangePt100/Pt200/Pt500/
Pt1000/Cu10/Cu50
Pt100/Pt200/Pt500/
Pt1000/Cu10/Cu50
Accuracy0.2℃0.2℃
Resolution0.1℃0.1℃
Frequency
(Hz)
Range1Hz ~110KHz1Hz ~110KHz
Accuracy±2words±2words
Resolution0.01Hz/1Hz/0.1KHz/2KHz0.01Hz/1Hz/0.1KHz/2KHz
Frequency(CMP)Range60~1200 CPM60~1200 CPM
Accuracy±2words±2words
Resolution1CPM1CPM
PulseFrequency1Hz ~10KHz1Hz ~10KHz
Range1 ~100000cyc1 ~100000cyc
Accuracy±2words±2words
Resolution1cyc1cyc
SwitchRange1Hz ~110KHz1Hz ~110KHz
Accuracy±2±2
Resolution0.01Hz/1Hz/0.1KHz/2KHz0.01Hz/1Hz/0.1KHz/2KHz
PressureRangeDepends on the pressure moduleDepends on the pressure module
Accuracy=
±(% of the set value+% of range)
Depends on the pressure moduleDepends on the pressure module
Resolution5 digit display5 digit display
MeasurementDC millivoltRange-5 ~ 550mV-5 ~ 550mV
Accuracy=
±( % of Reading+ % of Range)
0.01%+0.01%0.01%+0.01%
Resolution1uV/10uV1uV/10uV
DC voltageRange-0.5 ~ 35V-0.5 ~ 35V
Accuracy=
±( % of Reading+ % of Range)
0.01%+0.01%0.01%+0.01%
Resolution0.1mV/1mV0.1mV/1mV
DC currentRange-5 ~ 55mA-5 ~ 55mA
Accuracy
±( % of Reading+ % of Range)
0.01%+0.01%0.01%+0.01%
Resolution1uA1uA
ResistanceRange0 ~5.5KΩ0 ~5.5KΩ
Accuracy=
±( % of Reading+ % of Range)
0.01%+0.01%0.01%+0.01%
Resolution0.01Ω/0.1Ω0.01Ω/0.1Ω
ThermocoupleRangeR/S/K/E/J/T/B/N/L/UR/S/K/E/J/T/B/N/L/U
Accuracy0.7℃0.7℃
Resolution0.1℃/1℃0.1℃/1℃
RTDRangePt100/Pt200/Pt500/
Pt1000/Cu10/Cu50
Pt100/Pt200/Pt500/
Pt1000/Cu10/Cu50
Accuracy0.4℃0.4℃
Resolution0.1℃0.1℃
Frequency
(Hz)
Range3Hz ~50KHz3Hz ~50KHz
Accuracy±2words±2words
Resolution0.01Hz0.01Hz
Frequency(CMP)Range180~3000000 CPM180~3000000 CPM
Accuracy±2words±2words
Resolution1CPM1CPM
SwitchRangeCLOSE/OPENCLOSE/OPEN
Threshold200 ~300Ω200 ~300Ω
PressureRangeDepends on the pressure moduleDepends on the pressure module
Accuracy=
±( % of Reading+ % of Range)
Depends on the pressure moduleDepends on the pressure module
Resolution5 digit display5 digit display
Continuity beeperRange0 ~500Ω0 ~500Ω
Accuracy≤50Ωsound≤50Ωsound
Resolution0.01Ω0.01Ω
Loop power supplyRange24V24V
Accuracy±10%±10%
The maximum current22mA22mA
HART×
Other functions
Backlight
Auto Power-off
Charging function
Room temperature display
Battery detection
The ramp signal
Communication functionRS232 serial communication, can realize remote control instrument by the device driver software.RS232 serial communication, can realize remote control instrument by the device driver software.
Characteristic
SafetyEN61010-1:2001EN61010-1:2001
Withstand voltageThe input and output AC350V/1 minutesThe input and output AC350V/1 minutes
InsulationThe input and output DC500V /50MΩ.The input and output DC500V /50MΩ.
EMCEN61326-1:2006EN61326-1:2006
AuthenticationCECE
Display3.2“ TFT screen3.2“ TFT screen
Power supply4×1.5V AA Alkaline battery4×1.5V AA Alkaline battery
Size206 × 97 × 60 mm206 × 97 × 60 mm
Weightabout 633gabout 633g
Standard Quantity Per Carton6pcs6pcs
Standard Carton Measurement530mm*405mm*310mm530mm*405mm*310mm
Standard Carton Cross Weight12.6kg12.6kg

China VICTOR 26 Multifunction Process Calibrator Signal Generator With Accuracy Of 0.01%  5 Digits Display 24V loop circuit IP65 supplier