VICTOR 1800 Electric Power Tester Satellite Remote Distance Phase Detector

Brand Name:VICTOR
Certification:CE
Model Number:VICTOR 1800
Minimum Order Quantity:1pcs
Delivery Time:5 to 30 days
Payment Terms:T/T, Western Union, L/C, Paypal
Contact Now

Add to Cart

Active Member
Address: JINGYUAN 7 ROAD, JINGHE INDUSTRIAL PARK, NORTH DISTRICT,XI'AN,CHINA  710200
Supplier`s last login times: within 22 hours
Product Details Company Profile
Product Details

VICTOR 1800 Electric Power Tester Satellite Remote Distance Phase Detector


VICTOR 1800 Wireless High Voltage Satellite Remote Distance Phase Detector Frequency Phase Sequence Inspection 32 Tracking Channels

Brief Introduction

Wireless high voltage satellite remote distance phase instrument, also known as wireless high voltage satellite remote distance phase detector device, is composed of X receiver, Y receiver, X detector, Y detector, telescopic insulation rod and so on.

It can carry on the detecting phase of the power grid, cabinet, the middle cabinet and the switch cabinet, and has the function of the ordinary phase detecting instrument. The satellite timing core can achieve ultra long distance detected phase, basement phase detecting and underground phase detecting , and the time accuracy is less than 30nS.

The receiver uses a 3.5 inch real color LCD screen and a multi mode satellite timing module in one compose of six to support a variety of satellite navigation systems, including China's BDS (Beidou satellite navigation system), American GPS, Russian GLONASS, EU GALILEO, Japanese QZSS and satellite enhancement system SBAS (WAAS, EGNOS, GAGAN, MSAS).

It contains 32 tracking channels, which can receive GNSS signals from six satellite timing systems at the same time, and realize alliance time service to ensure accurate phase detecting.

The receiver displays live-time phase and frequency on the same screen, and has the voice prompt of "X signal normal, Y signal normal, phase to phase, phase difference" and so on, which is clear and intuitive. The distance of the common phase detector in the open ground is 160m around and the distance of the satellite timing phase detector is more than 500km.

It can be used for the full intelligent phase detecting of the voltage line of 10V to 550kV, and can also be used for the low voltage induction point and the high voltage line and the fully sealed circle grid power cabinet, in which the naked wires voltage under 35kV can directly contact the phase detector and the bare wire above the 35kV adopts non-contact, means detector is gradually close to the measuring wire, complete the phase detecting when received the induction of electric field signal , so there is no direct contact with hi-voltage wire, more safe! The phase detecting instrument also has the functions of high voltage electroscope, high voltage phase meter and high voltage phase sequence table. It can be used for power inspection, phase sequence test, transformer group judgement and so on.


Technology specification


FunctionWireless high voltage-satellite timing-phase detecting, frequency, phase, phase sequence, and electricity inspection.
PowerDC 3.7V rechargeable Li-battery,USB charge port,continually working 10h
Phase detectingSatellite second pulse precision mode, satellite timing mode, common mode
transmission mode315MHz,433MHz wireless transfer
Distance of phase detectingSatellite timing phase detector distance up to 500km
Common phase detector: 160m
Display mode3.5 LCD display
RangeRank of phase detecting:AC 10V~550kV
Phase degree:0°~360°
Frequency:45Hz~75Hz
Resolution1°;0.1Hz
Accuracy (23℃±5℃,80%RH below)Satellite phase Detector degree tolerance:≤±5°
Common detector tolerance:≤±10°
Frequency tolerance:≤±2Hz
Phase judgement

Same phase: XY receiver detected phase degree variance at range of 0°~30° ;

Heterogenous phase: XY receiver detected phase degree at range of 90°~120° or 210°~270°

Phonetic functionVoice report: Same phase, Heterogenous phase, normal X signal,normal Y signal
Satellite Timing validityOnce the satellite timing successfully, validity time over 30mins to meet the underground phase detecting.
Insulation rod lengthStretched length 5m;carrying on length 1m
Method of phase detectingContact:35kV below bare wire or 110kV with insulation skin.( testing with insulation rod)
Non-contact:35kV above bare wire or 110kV above.(testing with insulation rod)
Voice indicationThe sound of the probe "Du - Du - Du" buzz
Mode switchAutomatic shift
Sampling speed2times/sec
Connecting satellite timeAfter turning on detector, 1st search satellite takes 3min about, 2nd search satellite takes 30sec, The follow-up heat starts searching satellite time about 1 second, detector positive set up and keep level of heaven
Timing accuracyLess 30nS
Instrument sizeDetector: LxWxT 145mm×60mm×48mm
Receiver:LxWxT 250mm×100mm×40mm
Background brightness adjust

press ↑ ↓ adjust background brightness

Induction strength controlAccording to the different electric field of induction, the detector can automatically control magnification and facilitate the detecting phase in dense wire area.
Hold data1st Press HOLD to save date,2nd cancel date
QuitPress ESC button return interface
Data lookupPress ENTER look up data, press ↑↓ review
Symbol of satellite searchingDynamic display “----”symbol at period of search satellite
Automatically power offStandby 30min, then power off automatically for power saving
Rated currentdetector:35mA max;receiver:300mA max
Batter voltageThe detector low battery symbol display when voltage lower 3.2V, remind of charge battery
Instrument weightdetector:205g(contains battery)
receiver:395g(contains battery)
Insulation rod:1.45kg
Total weight:12.6kg(contains meter box)
Working humiture-10℃~40℃;80%Rh below
Storage humiture-10℃~60℃;70%Rh below
interfereNo interfere except especially Strong magnetic field, no interfere except same frequency 433MHz,315MHz
Insulation strengthInsulation rod:AC 110kV/rms(5sections after stretched)
detector:2000V/rms( rod connection ends to detector top)
receiver:2000V/rms(outer shell two ends )
structureAnti leak type II,IP63
Proper StandardGB13398 92, GB311.1 - 311.6 - 8, 3DL408 91 standard and national new electric power industry standard "DL/T971-2005 for universal technical conditions for portable 1kV to 35kV portable phase detector apparatus for live work"
Ideal for IEC61481-A2:2004;IEC 61243-1 ed.2:2003 standard